Whirlpool WGD7300XW Dimension Guide - Page 1
Whirlpool WGD7300XW Manual
UPC - 883049202334
View all Whirlpool WGD7300XW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Gas Dryer PRODUCT MODEL NUMBERS WGD6200S, WGD6600V, WGD6600W, WGD7300X, WGD7400X, WGD7600X, WGD7800X Gas supply: This dryer is equipped for use with Natural gas. Dryer can be converted to L.P. gas. When rigid pipe is used it should be 1/2" IPS. When acceptable to the gas supplier and local codes, 3/8" approved tubing may be used for lengths under 20 ft (6.1 m). For lengths over 20 ft (6.1 m), larger tubing should be used. Pipe-joint compounds resistant to the action of L.P. gas must be used. An individual manual shutoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code ANSI Z223.1. Electrical: A 120-volt, 60 Hz, AC-only, 15 or 20 amp fused electrical supply is required. A time-delay fuse or circuit breaker and a separate circuit are recommended. Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result. Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. Hood styles: A & B are recommended. B 4" C (102 mm) A 4" (102 mm) 4" (102 mm) 2½" (64 mm) A. Louvered hood B. Box hood C. Angled hood (acceptable) The vent system chart provides venting requirments that will help to achieve the best drying performance. Vent system chart: NOTE: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart. Number of 90o turns or elbows Type of vent Box or Louvered hoods Angled hoods 0 Rigid metal 64 ft (20 m) 58 ft (17.7 m) 1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m) 2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m) 3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m) 4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m) Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. Use the fewest 90° turns possible. Do not use vent runs longer than specified in vent length chart. Determine the number of elbows you will need. OVERALL DIMENSIONS Dryer dimensions 431/2" (1105 mm) 291/4" (743 mm) 29" (737 mm) 221/4" (565 mm) Cabinet and Closet dimensions 18"* (457 mm) 14" max.* (356 mm) 48" 2* (310 cm2) 3"* (76 mm) 1" (25 mm) 29" (737 mm) A 1" (25 mm) 291/4" (743 mm) B 24" 2* (155 cm2) 5" (127 mm) 3"* (76 mm) C For cabinet installation, with a door, the minimum ventilation openings in the top are required. For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable. Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice. Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice. Ref. W10261614B 05/2010