Whirlpool WRB119WFB Owners Manual - Page 21

Model UKF8001AXX-200/UKF8001 Capacity 200 Gallons 757 Liters, Water Filtration System

Page 21 highlights

Water Filtration System Model UKF8001AXX-200/UKF8001 Capacity 200 Gallons (757 Liters) System tested and certified by NSF International against NSF/ANSI Standard 42, 53, 401 and CSA B483.1 for the reduction of contaminants specified on the Performance Data Sheet. This system has been tested according to NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentraion less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42, 53, 401 and CSA B483.1. Substance Reduction Aesthetic Effects Influent Challenge Concentration Maximum Permissable Product Water Concentration Average% Reduction Chlorine Taste/Odor 2.0 mg/L ± 10% 50% reduction 97.6% Particulate Class I* At least 10,000 particles/mL 85% reduction 98.8% Contaminant Reduction Influent Challenge Concentration Maximum Permissable Product Water Concentration Average% Reduction Lead***: @ pH 6.5 / @ pH 8.5 0.150 mg/L ± 10% 0.010 mg/L 99.3% / 99.3% Mercury: @ pH 6.5 / @ pH 8.5 0.006 mg/L ± 10% 0.002 mg/L 95.1% / 95.0% Asbestos 107 to 108 fibers/L†† >99% >99% Cysts† 50,000/L min. >99.95% 99.99% Turbidity 11 NTU ± 10% 0.5 NTU 98.1% Atrazine 0.009 mg/L ± 10% 0.003 mg/L 94.4% Benzene 0.015 mg/L ± 10% 0.005 mg/L 96.6% Carbofuran 0.080 mg/L ± 10% 0.040 mg/L 86.8% Lindane 0.002 mg/L ± 10% 0.0002 mg/L 98.8% P-Dichlorobenzene 0.225 mg/L ± 10% 0.075 mg/L 99.7% Tetrachloroethylene 0.015 mg/L ± 10% 0.005 mg/L 96.0% Toxaphene 0.015 mg/L ± 10% 0.003 mg/L 93.8% Atenolol 200 ± 20% 30 ng/L >95.9% Endrin 0.006 mg/L± 10% 0.002 mg/L 96.7% Ethylbenzene 2.1 mg/L ± 10% 0.7 mg/L 99.9% o-Dichlorobenzene 1.8 mg/L± 10% 0.6 mg/L 99.9% 2,4 - D 0.210 mg/L ± 10% 0.07 mg/L 97% Carbamazepine 1400 ± 20% 200 ng/L >98.6% DEET 1400 ± 20% 200 ng/L >98.5% Linuron 140 ± 20% 20 ng/L >96.8% Meprobamate 400 ± 20% 60 ng/L 94.6% Metolachor 1400 ± 20% 200 ng/L 98.3% Trimethoprim 140 ± 20% 20 ng/L >96.4% Bisphenol A 2000 ± 20% 300 ng/L 99.4% Estrone 140 ± 20% 20 ng/L >96.7% Nonylphenol 1400 ± 20% 200 ng/L >98.9% Ibuprofen 400 ± 20% 60 ng/L 92.9% Naproxen 140 ± 20% 20 ng/L >96.3% Phenytoin 200 ± 20% 30 ng/L >94.8% Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.95 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters). The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging compounds/incidental contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the public acceptance/perception of drinking water quality. 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75

21
System tested and certified by NSF International against NSF/ANSI
Standard 42, 53, 401 and CSA B483.1 for the reduction of
contaminants specified on the Performance Data Sheet.
Water Filtration System
Model UKF8001AXX-200/UKF8001 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53, 401 and CSA
B483.1 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a concentraion less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42, 53, 401 and CSA B483.1.
Substance Reduction
Aesthetic Effects
Influent Challenge Concentration
Maximum Permissable
Product Water Concentration
Average% Reduction
Chlorine Taste/Odor
2.0 mg/L ± 10%
50% reduction
97.6%
Particulate Class I*
At least 10,000 particles/mL
85% reduction
98.8%
Contaminant Reduction
Influent Challenge Concentration
Maximum Permissable
Product Water Concentration
Average% Reduction
Lead***: @ pH 6.5 / @ pH 8.5
0.150 mg/L ± 10%
0.010 mg/L
99.3% / 99.3%
Mercury: @ pH 6.5 / @ pH 8.5
0.006 mg/L ± 10%
0.002 mg/L
95.1% / 95.0%
Asbestos
10
7
to 10
8
fibers/L††
>99%
>99%
Cysts†
50,000/L min.
>99.95%
99.99%
Turbidity
11 NTU ± 10%
0.5 NTU
98.1%
Atrazine
0.009 mg/L ± 10%
0.003 mg/L
94.4%
Benzene
0.015 mg/L ± 10%
0.005 mg/L
96.6%
Carbofuran
0.080 mg/L ± 10%
0.040 mg/L
86.8%
Lindane
0.002 mg/L ± 10%
0.0002 mg/L
98.8%
P-Dichlorobenzene
0.225 mg/L ± 10%
0.075 mg/L
99.7%
Tetrachloroethylene
0.015 mg/L ± 10%
0.005 mg/L
96.0%
Toxaphene
0.015 mg/L ± 10%
0.003 mg/L
93.8%
Atenolol
200 ± 20%
30 ng/L
>95.9%
Endrin
0.006 mg/L± 10%
0.002 mg/L
96.7%
Ethylbenzene
2.1 mg/L ± 10%
0.7 mg/L
99.9%
o-Dichlorobenzene
1.8 mg/L± 10%
0.6 mg/L
99.9%
2,4 - D
0.210 mg/L ± 10%
0.07 mg/L
97%
Carbamazepine
1400 ± 20%
200 ng/L
>98.6%
DEET
1400 ± 20%
200 ng/L
>98.5%
Linuron
140 ± 20%
20 ng/L
>96.8%
Meprobamate
400 ± 20%
60 ng/L
94.6%
Metolachor
1400 ± 20%
200 ng/L
98.3%
Trimethoprim
140 ± 20%
20 ng/L
>96.4%
Bisphenol A
2000 ± 20%
300 ng/L
99.4%
Estrone
140 ± 20%
20 ng/L
>96.7%
Nonylphenol
1400 ± 20%
200 ng/L
>98.9%
Ibuprofen
400 ± 20%
60 ng/L
92.9%
Naproxen
140 ± 20%
20 ng/L
>96.3%
Phenytoin
200 ± 20%
30 ng/L
>94.8%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.95 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.