Yamaha 01V96i Owner's Manual - Page 28

Specifying the Wordclock, Source, Press the DISPLAY ACCESS [DIO/SETUP]

Page 28 highlights

28 Connections and Setup Specifying the Wordclock Source To digitally connect the 01V96i to external devices, you must specify the wordclock source for the system. Follow the steps below. Note: When you change the wordclock settings on any device in your digital audio system, some devices may output noise due to being out of synchronization. Be sure to turn down your monitoring device before changing wordclock settings. 1. Press the DISPLAY ACCESS [DIO/SETUP] button repeatedly until the DIO/Setup | Word Clock page appears. On this page, you can view the current synchronization status of input signals at each slot and connector. The source select button indicators are explained below: A usable wordclock signal is present at this input, and it is in sync with the current 01V96i internal clock. No wordclock signal is present at this input. A usable wordclock signal is present at this input, but it is out of sync with the current 01V96i internal clock. This input is the currently-selected wordclock source. This input was selected as the wordclock source, but no usable signal was received. Either this input is not receiving wordclock, or else it cannot be used with the currently-installed I/O card. Tip: • The FS box displays the sampling frequency at which the 01V96i is currently operating. • The SLOT TYPE column displays the names of any installed I/O card. • The IN and OUT columns indicate the number of input and output channels available for each installed I/O card. 2. Use the cursor buttons to move the cur- sor to a source, then press [ENTER]. The following are possible wordclock sources. However, USB only displays the synchronization status, and cannot be selected as the wordclock master. • SLOT These buttons select the inputs from the digital I/O card installed in the slot as the wordclock source. Inputs are selected in pairs (odd and even numbers in this order). The SLOT TYPE column displays the names of any installed I/O card. The number of pairs depends on the type of I/O card installed. • adat These buttons select the inputs from the ADAT IN connector on the rear panel. Inputs are selected in pairs (odd and even numbers in this order). • WC IN This button selects the wordclock signal input at the WORD CLOCK IN connector on the rear panel. • 2TRD This button selects the 2TR IN DIGITAL input as the wordclock source. • INT 44.1k, INT 48k, INT 88.2k, INT 96k These buttons select the internal clock generator as the wordclock source. The 01V96i will function as the wordclock master. • USB (display only) This indicates the synchronization status of the signal being input from the TO HOST USB port. It cannot be selected as the wordclock master. Note: To transfer data at higher sampling frequencies (88.2 kHz or 96 kHz) between the 01V96i and connected external devices, you need to set the data transfer format. Tip: If wordclock transfer is interrupted while the 01V96i (being used as a slave unit) is receiving the clock signal, the unit will automatically switch to an internal clock (INT 44.1k/ INT 48k/INT 88.2k/INT 96k) that is closest to the interrupted clock. 01V96i-Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

28
Connections and Setup
01V96i—Owner’s Manual
Specifying the Wordclock
Source
To digitally connect the 01V96i to external devices, you
must specify the wordclock source for the system. Fol-
low the steps below.
1.
Press the DISPLAY ACCESS [DIO/SETUP]
button repeatedly until the DIO/Setup |
Word Clock page appears.
On this page, you can view the current synchroni-
zation status of input signals at each slot and con-
nector.
The source select button indicators are explained
below:
A usable wordclock signal is present at this
input, and it is in sync with the current 01V96i
internal clock.
No wordclock signal is present at this input.
A usable wordclock signal is present at this
input, but it is out of sync with the current
01V96i internal clock.
This input is the currently-selected wordclock
source.
This input was selected as the wordclock
source, but no usable signal was received.
Either this input is not receiving wordclock, or
else it cannot be used with the cur-
rently-installed I/O card.
2.
Use the cursor buttons to move the cur-
sor to a source, then press [ENTER].
The following are possible wordclock sources.
However, USB only displays the synchronization
status, and cannot be selected as the wordclock
master.
SLOT
These buttons select the inputs from the digital I/O
card installed in the slot as the wordclock source.
Inputs are selected in pairs (odd and even numbers
in this order). The SLOT TYPE column displays the
names of any installed I/O card. The number of
pairs depends on the type of I/O card installed.
adat
These buttons select the inputs from the ADAT IN
connector on the rear panel. Inputs are selected in
pairs (odd and even numbers in this order).
WC IN
This button selects the wordclock signal input at the
WORD CLOCK IN connector on the rear panel.
2TRD
This button selects the 2TR IN DIGITAL input as
the wordclock source.
INT 44.1k, INT 48k, INT 88.2k, INT 96k
These buttons select the internal clock generator as
the wordclock source. The 01V96i will function as
the wordclock master.
USB (display only)
This indicates the synchronization status of the sig-
nal being input from the TO HOST USB port. It
cannot be selected as the wordclock master.
Note:
When you change the wordclock settings on any
device in your digital audio system, some devices may out-
put noise due to being out of synchronization. Be sure to
turn down your monitoring device before changing word-
clock settings.
Tip:
The FS box displays the sampling frequency at which the
01V96i is currently operating.
The SLOT TYPE column displays the names of any
installed I/O card.
The IN and OUT columns indicate the number of input
and output channels available for each installed I/O
card.
Note:
To transfer data at higher sampling frequencies
(88.2 kHz or 96 kHz) between the 01V96i and connected
external devices, you need to set the data transfer format.
Tip:
If wordclock transfer is interrupted while the 01V96i
(being used as a slave unit) is receiving the clock signal, the
unit will automatically switch to an internal clock (INT
44.1k/ INT 48k/INT 88.2k/INT 96k) that is closest to the
interrupted clock.