MIDI Event Channel Pressure (Aftertouch) [GM2] [MIDI (CLP)] Data Format MIDI Reception (effective or not for each part) Song Main Layer Left Left-layer Keyboard MIDI Reception (affecting the panel) F0 7F XN 09 01 0M PP RR ... F7     11110000 F0 = Exclusive status 01111111 7F = Universal Real Time 0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored 00001001 09 = Sub-ID #1=Controller Destination Setting 00000001 01 = Sub-ID #2=Controller Type: 01 (Channel Pressure) 0000mmmm 0M = MIDI Channel (00-0F) 0ppppppp PP = Controlled Parameter 0rrrrrrr RR = Data ... ... 11110111 F7 = End of Exclusive MIDI Transmission (generated data) Panel (main generation method) Song   (Changed to XG, and output) [Internal Sequencer] PLAY REC Recorded MIDI PLAY REW from panel   Control Parameter (pp) Data (RR) Description Default value pp=00 Pitch Control 28H-58H -24...0...+24 semitones 40H pp=01 Filter Cutoff Control 00H-7FH -9600...0...+9450 cents 40H pp=02 Amplitude Control 00H-7FH -100...0...+100% 40H pp=03 LFO Pitch Depth 00H-7FH 0...127 00H pp=04 LFO Filter Depth 00H-7FH 0...127 00H pp=05 LFO Amplitude Depth 00H-7FH 0...127 00H Controller F0 7F XN 09 03 0M CC PP RR ... F7     (Control Change) 11110000 F0 = Exclusive status [GM2] 01111111 7F = Universal Real Time 0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored 00001001 09 = Sub-ID #1=Controller Destination Setting 00000011 03 = Sub-ID #2=Controller Type: 03 (Control Change) 0000mmmm 0M = MIDI Channel (00-0F) 0ccccccc CC = Controller Number (01H-1FH, 40H-5FH) 0ppppppp PP = Controlled Parameter 0rrrrrrr RR = Data ... ... 11110111 F7 = End of Exclusive     (Changed to XG, and output) Make sure to set both the controlled parameter and the range. Parameters not set will be restored to their default values. Control Parameter (pp) Data (RR) Description Default value pp=00 Pitch Control 28H-58H -24...0...+24 semitones 40H pp=01 Filter Cutoff Control 00H-7FH -9600...0...+9450 cents 40H pp=02 Amplitude Control 00H-7FH -100...0...+100% 40H pp=03 LFO Pitch Depth 00H-7FH 0...127 00H pp=04 LFO Filter Depth 00H-7FH 0...127 00H pp=05 LFO Amplitude Depth 00H-7FH 0...127 00H Key-Based Instrument F0 7F XN 0A 01 0M KK CC VV ... F7     Control 11110000 F0 = Exclusive status [GM2] 01111111 7F = Universal Real Time 0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored 00001010 0A = Sub-ID #1=Key-Based Instrument Control 00000011 01 = Sub-ID #2=Controller 0000mmmm 0M = MIDI Channel (00-0F) 0kkkkkkk KK = Key Number 0ccccccc CC = Controller Number 0vvvvvvv VV = Value ... ... 11110111 F7 = End of Exclusive     (Changed to XG, and output) Make sure to set both the controlled number and the value. Control Number (CC) Value (VV) Description Default value CC=07H Volume 00H-7FH -100...0...+100% 40 CC=0AH Pan 00H-7FH L63...C...R63 (Preset value) (absolute) CC=5BH Reverb Send Level 00H-7FH 0...Max (Preset value) (absolute) CC=5DH Chorus Send Level 00H-7FH 0...Max (Preset value) (absolute) CLP-480 Data List Complete Version 35 MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

CLP-480 Data List
Complete Version
MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI
35
Channel Pressure
(Aftertouch)
[GM2]
F0
7F
XN
09
01
0M
PP
RR
... F7
11110000
F0
= Exclusive status
01111111
7F
= Universal Real Time
0xxxnnnn
XN = When N is received N=0-F, whichever is received. X=ignored
00001001
09
= Sub-ID #1=Controller Destination Setting
00000001
01
= Sub-ID #2=Controller Type: 01 (Channel Pressure)
0000mmmm
0M = MIDI Channel (00-0F)
0ppppppp
PP
= Controlled Parameter
0rrrrrrr
RR = Data
...
...
11110111
F7
= End of Exclusive
Control Parameter (pp)
Data (RR)
Description
Default value
-------------------------------------------------------------------------------------------------------
pp=00 Pitch Control
28H-58H
-24...0...+24 semitones
40H
pp=01 Filter Cutoff Control
00H-7FH
-9600...0...+9450 cents
40H
pp=02 Amplitude Control
00H-7FH
-100...0...+100%
40H
pp=03 LFO Pitch Depth
00H-7FH
0...127
00H
pp=04 LFO Filter Depth
00H-7FH
0...127
00H
pp=05 LFO Amplitude Depth
00H-7FH
0...127
00H
(Changed to
XG, and
output)
Controller
(Control Change)
[GM2]
F0
7F
XN
09
03
0M
CC
PP
RR
... F7
11110000
F0
= Exclusive status
01111111
7F
= Universal Real Time
0xxxnnnn
XN = When N is received N=0-F, whichever is received. X=ignored
00001001
09
= Sub-ID #1=Controller Destination Setting
00000011
03
= Sub-ID #2=Controller Type: 03 (Control Change)
0000mmmm
0M = MIDI Channel (00-0F)
0ccccccc
CC = Controller Number (01H-1FH, 40H-5FH)
0ppppppp
PP
= Controlled Parameter
0rrrrrrr
RR = Data
...
...
11110111
F7
= End of Exclusive
Make sure to set both the controlled parameter and the range.
Parameters not set will be restored to their default values.
Control Parameter (pp)
Data (RR)
Description
Default value
-------------------------------------------------------------------------------------------------------
pp=00 Pitch Control
28H-58H
-24...0...+24 semitones
40H
pp=01 Filter Cutoff Control
00H-7FH
-9600...0...+9450 cents
40H
pp=02 Amplitude Control
00H-7FH
-100...0...+100%
40H
pp=03 LFO Pitch Depth
00H-7FH
0...127
00H
pp=04 LFO Filter Depth
00H-7FH
0...127
00H
pp=05 LFO Amplitude Depth
00H-7FH
0...127
00H
(Changed to
XG, and
output)
Key-Based Instrument
Control
[GM2]
F0
7F
XN
0A
01
0M
KK
CC
VV
... F7
11110000
F0
= Exclusive status
01111111
7F
= Universal Real Time
0xxxnnnn
XN = When N is received N=0-F, whichever is received. X=ignored
00001010
0A
= Sub-ID #1=Key-Based Instrument Control
00000011
01
= Sub-ID #2=Controller
0000mmmm
0M = MIDI Channel (00-0F)
0kkkkkkk
KK = Key Number
0ccccccc
CC = Controller Number
0vvvvvvv
VV
= Value
...
...
11110111
F7
= End of Exclusive
Make sure to set both the controlled number and the value.
Control Number (CC)
Value (VV)
Description
Default value
-------------------------------------------------------------------------------------------------------
CC=07H Volume
00H-7FH
-100...0...+100%
40
CC=0AH Pan
00H-7FH
L63...C...R63
(Preset value)
(absolute)
CC=5BH Reverb Send Level
00H-7FH
0...Max
(Preset value)
(absolute)
CC=5DH Chorus Send Level
00H-7FH
0...Max
(Preset value)
(absolute)
(Changed to
XG, and
output)
[MIDI (CLP)]
[Internal Sequencer]
MIDI Event
Data Format
MIDI Reception
(effective or not for each part)
MIDI
Reception
(affecting the
panel)
MIDI Transmission
(generated data)
PLAY
REC
Song
Main
Layer
Left
Left-layer
Keyboard
Panel
(main
generation
method)
Song
MIDI
PLAY
REW
Recorded
from
panel