Yamaha CVP-805 CVP-809/CVP-805 Data List - Page 125

MIDI Reception, MIDI Event

Page 125 highlights

MIDI Event Data Format Channel Pressure (Aftertouch) F0 7F XN 09 01 0M PP RR ... F7 [GM2] 11110000 01111111 0xxxnnnn 00001001 00000001 0000mmmm 0ppppppp 0rrrrrrr ... 11110111 F0 = Exclusive status 7F = Universal Real Time XN = When N is received N=0-F, whichever is received. X=ignored 09 = Sub-ID #1= Controller Destination Setting 01 = Sub-ID #2= Controller Type: 01 (Channel Pressure) 0M = MIDI Channel (00-0F) PP = Controlled Parameter RR = Data ... F7 = End of Exclusive [MIDI] Voice Regular/ Drum/ Mic/ Natural/ Vocal Song Organ Harmony Flutes    MIDI Reception Main/ Layer/Left Keyboard Style    Extra  MIDI Transmission [Internal Sequencer] PLAY REC Main/ Layer/Left Style Song Upper Lower PLAY From panel REW (Main/ Layer/Left)   Make sure to set both the controlled parameter and the range. Parameters not set will be restored to their default values. Control Parameter (pp) Data (RR) Description Default Value pp=00 Pitch Control 28H-58H -24...0...+24semitones 40H pp=01 Filter Cutoff Control 00H-7FH -9600...0...+9450cents 40H pp=02 Amplitude Control 00H-7FH -100...0...+100% 40H pp=03 LFO Pitch Depth 00H-7FH 0...127 00H pp=04 LFO Filter Depth 00H-7FH 0...127 00H pp=05 LFO Amplitude Depth 00H-7FH 0...127 00H Controller (Control Change) F0 7F XN 09 03 0M CC PP RR ... F7  [GM2] 11110000 01111111 0xxxnnnn 00001001 00000011 0000mmmm 0ccccccc 0ppppppp 0rrrrrrr ... 11110111 F0 = Exclusive status 7F = Universal Real Time XN = When N is received N=0-F, whichever is received. X=ignored 09 = Sub-ID #1 = Controller Destination Setting 03 = Sub-ID #2 = Controller Type: 03 (Control Change) 0M = MIDI Channel (00-0F) CC = Controller Number (01H-1FH, 40H-5FH) PP = Controlled Parameter RR = Range ... F7 = End of Exclusive Make sure to set both the controlled parameter and the range. Parameters not set will be restored to their default values.        Control Parameter (pp) Data (RR) Description Default Value pp=00 Pitch Control 28H-58H -24...0...+24semitones 40H pp=01 Filter Cutoff Control 00H-7FH -9600...0...+9450cents 40H pp=02 Amplitude Control 00H-7FH -100...0...+100% 40H pp=03 LFO Pitch Depth 00H-7FH 0...127 00H pp=04 LFO Filter Depth 00H-7FH 0...127 00H pp=05 LFO Amplitude Depth 00H-7FH 0...127 00H Key-Based Instrument Control F0 7F XN 0A 01 0M KK CC VV ... F7     [GM2] 11110000 F0 = Exclusive status (Drum only) 01111111 7F = Universal Real Time 0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored 00001010 0A = Sub-ID #1 = Key-Based Instrument Control 00000001 01 = Sub-ID #2= Controller 0000mmmm 0M = MIDI Channel (00-0F) 0kkkkkkk KK = Key Number 0ccccccc CC = Controller Number 0vvvvvvv VV = Value ... ... 11110111 F7 = End of Exclusive Make sure to set both the controlled parameter and the value.     Control Number (CC) Value (VV) Description Default Value CC=07H Volume 00H-7FH -100...0...+100% 40H CC=0AH Pan 00H-7FH -L63...C...R63 (Preset value) (absolute) CC=5BH Reverb Send Level 00H-7FH 0...Max (Preset value) (absolute) CC=5DH Chorus Send Level 00H-7FH 0...Max (Preset value) (absolute) CVP-809/CVP-805 Data List MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI 125

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

CVP-809/CVP-805 Data List
MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI
125
Channel Pressure (Aftertouch)
F0 7F XN 09 01 0M PP RR … F7
[GM2]
11110000
F0
= Exclusive status
01111111
7F
= Universal Real Time
0xxxnnnn
XN
= When N is received N=0-F, whichever is received. X=ignored
00001001
09
= Sub-ID #1= Controller Destination Setting
00000001
01
= Sub-ID #2= Controller Type: 01 (Channel Pressure)
0000mmmm
0M = MIDI Channel (00-0F)
0ppppppp
PP
= Controlled Parameter
0rrrrrrr
RR
= Data
11110111
F7
= End of Exclusive
Make sure to set both the controlled parameter and the range.
Parameters not set will be restored to their default values.
Control Parameter (pp)
Data (RR)
Description
Default Value
------------------------------------------------------------------------------------
pp=00 Pitch Control
28H-58H
-24…0…+24semitones 40H
pp=01 Filter Cutoff Control
00H-7FH
-9600…0…+9450cents 40H
pp=02 Amplitude Control
00H-7FH
-100…0…+100%
40H
pp=03 LFO Pitch Depth
00H-7FH
0…127
00H
pp=04 LFO Filter Depth
00H-7FH
0…127
00H
pp=05 LFO
Amplitude Depth
00H-7FH
0…127
00H
Controller (Control Change)
F0 7F XN 09 03 0M CC PP RR … F7
[GM2]
11110000
F0
= Exclusive status
01111111
7F
= Universal Real Time
0xxxnnnn
XN
= When N is received N=0-F, whichever is received. X=ignored
00001001
09
= Sub-ID #1 = Controller Destination Setting
00000011
03
= Sub-ID #2 = Controller Type: 03 (Control Change)
0000mmmm
0M = MIDI Channel (00-0F)
0ccccccc
CC = Controller Number (01H-1FH, 40H-5FH)
0ppppppp
PP
= Controlled Parameter
0rrrrrrr
RR
= Range
11110111
F7
= End of Exclusive
Make sure to set both the controlled parameter and the range.
Parameters not set will be restored to their default values.
Control Parameter (pp)
Data (RR)
Description
Default Value
------------------------------------------------------------------------------------
pp=00 Pitch Control
28H-58H
-24…0…+24semitones 40H
pp=01 Filter Cutoff Control
00H-7FH
-9600…0…+9450cents 40H
pp=02 Amplitude Control
00H-7FH
-100…0…+100%
40H
pp=03 LFO Pitch Depth
00H-7FH
0…127
00H
pp=04 LFO Filter Depth
00H-7FH
0…127
00H
pp=05 LFO
Amplitude Depth
00H-7FH
0…127
00H
Key-Based Instrument Control
F0 7F XN 0A 01 0M KK CC VV … F7
(Drum only)
[GM2]
11110000
F0
= Exclusive status
01111111
7F
= Universal Real Time
0xxxnnnn
XN
= When N is received N=0-F, whichever is received. X=ignored
00001010
0A
= Sub-ID #1 = Key-Based Instrument Control
00000001
01
= Sub-ID #2= Controller
0000mmmm
0M = MIDI Channel (00-0F)
0kkkkkkk
KK
= Key Number
0ccccccc
CC = Controller Number
0vvvvvvv
VV
= Value
11110111
F7
= End of Exclusive
Make sure to set both the controlled parameter and the value.
Control Number (CC)
Value (VV)
Description
Default Value
----------------------------------------------------------------------------------
CC=07H Volume
00H-7FH
-100…0…+100%
40H
CC=0AH Pan
00H-7FH
-L63…C…R63
(Preset value)
(absolute)
CC=5BH Reverb Send Level
00H-7FH
0…Max
(Preset value)
(absolute)
CC=5DH Chorus Send Level 00H-7FH
0…Max
(Preset value)
(absolute)
[MIDI]
[Internal Sequencer]
MIDI Event
Data Format
Voice
MIDI Reception
MIDI Transmission
PLAY
REC
Regular/
Drum/
Natural/
Organ
Flutes
Mic/
Vocal
Harmony
Song
Main/
Layer/Left
Keyboard
Style
Extra
Main/
Layer/Left
Style
Song
Upper
Lower
PLAY
REW
From panel
(Main/
Layer/Left)