Yamaha MOX6 Reference Manual - Page 149

BankSel Bank Select, PgmChange Program Change, LocalCtrl Local Control, RcvBulk Receive Bulk

Page 149 highlights

VOICE PERF SONG PATTERN MIX MASTER REMOTE UTILITY QUICK SET FILE [SF2] SWITCH BankSel (Bank Select) This switch enables or disables Bank Select messages, both in transmission and reception. When this is set to "on," this synthesizer responds to incoming Bank Select messages, and it also transmits appropriate Bank Select messages (when using the panel). Settings: off, on PgmChange (Program Change) This switch enables or disables Program Change messages, both in transmission and reception. When this is set to "on," this synthesizer responds to incoming Program Change messages, and it also transmits appropriate Program Change messages (when using the panel). Settings: off, on LocalCtrl (Local Control) This determines whether or not the tone generator of the instrument responds to your keyboard playing. Normally, this should be set to "on" - since you'll want to hear the sound of the MOX6/MOX8 as you play it. Even if this is set to "off," the data will be transmitted via MIDI. Also, the internal tone generator block will respond to messages received via MIDI. Settings: off (disconnect), on (connect) RcvBulk (Receive Bulk) Determines whether or not Bulk Dump data can be received. Settings: protect (not received), on (received) Utility Mode [F1] GENERAL [F2] VOICE [F2] SEQ [F3] VCE A/D [F4] CTL ASN [F5] USB I/O [F6] MIDI Utility Job [SF3] SYNC (Synchronization) From this display you can set various parameters related to MIDI clock and synchronization. MIDI Sync Determines whether Song/Pattern/Arpeggio playback will be synchronized to the instrument's internal clock or an external MIDI clock. Settings: internal, external, auto, MTC internal Synchronization to internal clock. You can use this setting when this tone generator is to be used alone or as the master clock source for other equipment. external Synchronization to a MIDI clock received from an external MIDI instrument via MIDI. Use this setting when the external sequencer is to be used as master. auto When MIDI clock is transmitted continuously from an external MIDI device or computer, the internal clock of the MOX6/MOX8 is automatically disabled and the MOX6/MOX8 is synchronized with the external clock. When MIDI clock is not transmitted from the external MIDI device or computer, the internal clock of the MOX6/MOX8 continues to run in sync with the latest received tempo of the external MIDI device or computer (DAW software). This setting is useful when you wish to alternate between external clock and internal clock. MTC (MIDI Time Code) ....Synchronization to an MTC signal received via MIDI. MMC signals are transmitted via MIDI. Use this setting when this synthesizer is to be used as a MIDI slave, such as when synchronized to an MTCcapable MTR. The MTC Sync function is available only in the Song mode. NOTE When MIDI Sync is set to "MTC," Songs and Arpeggios cannot play back in the Song mode but Patterns and Arpeggios can play back in the Pattern mode. NOTE MTC (MIDI Time Code) allows simultaneous synchronization of multiple audio devices via standard MIDI cables. It includes data corresponding to hours, minutes, seconds, and frames. The MOX6/MOX8 does not transmit MTC. NOTE MMC (MIDI Machine Control) allows remote control of multi Track recorders, MIDI sequencers, etc. A MMC-compatible multi Track recorder, for example, will automatically respond to start, stop, fast forward, and fast reverse operations performed on the controlling sequencer, thus keeping playback of the sequencer and multi Track recorder aligned. NOTE When setting the MOX6/MOX8 so that Arpeggio playback is synchronized to an external MIDI clock, make sure to set the devices so that the MIDI clock from the DAW software/ external MIDI device is properly transmitted to the MOX6/MOX8 from the DAW software/ external MIDI devices. ClockOut Determines whether MIDI clock (F8) messages will be transmitted via the MIDI OUT/USB terminal. Settings: off, on SeqCtrl (Sequencer Control) Determines whether Sequencer Control signals - start, continue, stop, and song position pointer - will be received and/or transmitted via MIDI. Settings: off, in, out, in/out off Not transmitted/recognized. in Recognized, but not transmitted. out Transmitted, but not recognized. in/out Transmitted/recognized. MOX6/MOX8 Reference Manual 149

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160

PERF
SONG
PATTERN
MIX
MASTER
REMOTE
UTILITY
QUICK SET
FILE
VOICE
MOX6/MOX8 Reference Manual
Utility Mode
[F1] GENERAL
[F2] VOICE
[F2] SEQ
[F3] VCE A/D
[F4] CTL ASN
[F5] USB I/O
[F6] MIDI
Utility Job
149
[SF2] SWITCH
BankSel (Bank Select)
This switch enables or disables Bank Select messages, both in transmission and reception. When this is set to “on,” this
synthesizer responds to incoming Bank Select messages, and it also transmits appropriate Bank Select messages
(when using the panel).
Settings:
off, on
PgmChange (Program Change)
This switch enables or disables Program Change messages, both in transmission and reception. When this is set to
“on,” this synthesizer responds to incoming Program Change messages, and it also transmits appropriate Program
Change messages (when using the panel).
Settings:
off, on
LocalCtrl (Local Control)
This determines whether or not the tone generator of the instrument responds to your keyboard playing. Normally, this
should be set to “on” — since you’ll want to hear the sound of the MOX6/MOX8 as you play it. Even if this is set to “off,”
the data will be transmitted via MIDI. Also, the internal tone generator block will respond to messages received via MIDI.
Settings:
off (disconnect), on (connect)
RcvBulk (Receive Bulk)
Determines whether or not Bulk Dump data can be received.
Settings:
protect (not received), on (received)
[SF3] SYNC (Synchronization)
From this display you can set various parameters related to MIDI clock and synchronization.
MIDI Sync
Determines whether Song/Pattern/Arpeggio playback will be synchronized to the instrument’s internal clock or an
external MIDI clock.
Settings:
internal, external, auto, MTC
internal
..............................
Synchronization to internal clock. You can use this setting when this tone generator is to be used
alone or as the master clock source for other equipment.
external
.............................
Synchronization to a MIDI clock received from an external MIDI instrument via MIDI. Use this setting
when the external sequencer is to be used as master.
auto
...................................
When MIDI clock is transmitted continuously from an external MIDI device or computer, the internal
clock of the MOX6/MOX8 is automatically disabled and the MOX6/MOX8 is synchronized with the
external clock. When MIDI clock is not transmitted from the external MIDI device or computer, the
internal clock of the MOX6/MOX8 continues to run in sync with the latest received tempo of the
external MIDI device or computer (DAW software). This setting is useful when you wish to alternate
between external clock and internal clock.
MTC (MIDI Time Code)
....
Synchronization to an MTC signal received via MIDI. MMC signals are transmitted via MIDI. Use this
setting when this synthesizer is to be used as a MIDI slave, such as when synchronized to an MTC-
capable MTR. The MTC Sync function is available only in the Song mode.
NOTE
When MIDI Sync is set to “MTC,” Songs and Arpeggios cannot play back in the Song mode but Patterns and Arpeggios can
play back in the Pattern mode.
NOTE
MTC (MIDI Time Code) allows simultaneous synchronization of multiple audio devices via standard MIDI cables. It includes data
corresponding to hours, minutes, seconds, and frames. The MOX6/MOX8 does not transmit MTC.
NOTE
MMC (MIDI Machine Control) allows remote control of multi Track recorders, MIDI sequencers, etc. A MMC-compatible multi
Track recorder, for example, will automatically respond to start, stop, fast forward, and fast reverse operations performed on the
controlling sequencer, thus keeping playback of the sequencer and multi Track recorder aligned.
NOTE
When setting the MOX6/MOX8 so that Arpeggio playback is synchronized to an external MIDI clock, make sure to set the
devices so that the MIDI clock from the DAW software/ external MIDI device is properly transmitted to the MOX6/MOX8 from the
DAW software/ external MIDI devices.
ClockOut
Determines whether MIDI clock (F8) messages will be transmitted via the MIDI OUT/USB terminal.
Settings:
off, on
SeqCtrl (Sequencer Control)
Determines whether Sequencer Control signals — start, continue, stop, and song position pointer — will be received
and/or transmitted via MIDI.
Settings:
off, in, out, in/out
off
.......................
Not transmitted/recognized.
in
........................
Recognized, but not transmitted.
out
......................
Transmitted, but not recognized.
in/out
..................
Transmitted/recognized.