Yamaha MY4-AEC MTX5-D/MY4-AEC System Setup Manual - Page 11
Example 2) One remote location, and eight microphones in the meeting room
View all Yamaha MY4-AEC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Example 2) One remote location, and eight microphones in the meeting room Microphone 1 Microphone 2 Microphone 3 Microphone 4 Microphone 5 Microphone 6 Microphone 7 Microphone 8 Analog OUT Meeting room XMV4140 Analog IN YDIF MTX5-D Analog IN/OUT CODEC Network Remote A In this example, the signal flow is as follows. Adjustable parameter Non-adjustable parameter Signal path with adjustable parameters Signal path with non-adjustable parameters Input Matrix Zone Output AEC Mic In 8 ch ([INPUT] 1-8) Direct Ch 8 ch 17-24 CODEC ([ST IN] 1L) 1 ch InputCh 1 ch 9 Matrix 4 ch 11-14 Matrix 10 1 ch ZONE 4 ch 11-14 ZONE 10 1 ch OutputCh 4 ch 6-9 OutputCh 1 ch 5 NE NEVoice FromFE Secondary FBS FEVoice NR = ON NR = ON To FE 4 ch 1 ch 4 ch Primary FBS InputCh 4 ch 5-8 Input Ch 1 ch 10 InputCh 4 ch 1-4 Matrix 9 1 ch Matrix 1 1 ch ZONE 9 1 ch ZONE 1 1 ch OutputCh 1 ch XMV 2 YDIF 1 (A ch) OutputCh 1 ch 1 CODEC ([OUTPUT] 1) MTX5-D/MY4-AEC System Setup Manual 11