Yamaha Tyros2 Data List - Page 31

Effect Parameter List / Liste der Effektparameter / Liste des paramètres d'effets, LARGE HALL

Page 31 highlights

Effect Parameter List / Liste der Effektparameter / Liste des paramètres d'effets Parameters marked with a ● in the "Control" column can be controlled from an AC1 (assignable controller 1) etc. However, these only affect insertion type effects. Panel Effect Name HALL1, 2, 3, 4, 5, HALLM, HALLL ROOM1, 2, 3, 4, 5, 6, 7, ROOMS, ROOMM, ROOML STAGE1, 2, 3, 4 PLATE1, 2, 3, GM PLATE (Reverb, all the DSP blocks) No. Parameter 1 Reverb Time 2 Diffusion 3 Initial Delay 4 HPF Cutoff 5 LPF Cutoff 6 7 8 9 10 Dry/Wet Display 0.3 - 30.0s 0 - 10 0.1mS - 200.0mS (*1) 0.1mS - 99.3mS (*2) Thru - 8.0kHz 1.0kHz - Thru D63>W - D=W - DR - E=R - EW - D=W - DW - D=W - DW - D=W - DW - D=W - DR Delay 2 R->L Delay 3 Feedback Level 4 Input Select 5 High Damp 6 7 8 9 10 Dry/Wet Display 0.1 - 1486.0ms 0.1 - 1486.0ms -63 - +63 L, R, L&R 0.1 - 1.0 MSB = 08 Value 1 - 14860 1 - 14860 1 - 127 0 - 2 1 - 10 See Table (table#16) Control D63>W - D=W - D

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

31
Tyros2 Data List
Effect Parameter List / Liste der Effektparameter / Liste des paramètres d’effets
Panel Effect Name
Type MSB (Type LSB)
HALL1, 2, 3, 4, 5, HALLM, HALLL
MSB = 01,
LSB = 0, 1, 6, 7, 16, 17, 18
ROOM1, 2, 3, 4, 5, 6, 7, ROOMS, ROOMM, ROOML
MSB = 0, 2,
LSB = 0, 1, 2, 5, 6, 7, 16, 17, 18, 19
STAGE1, 2, 3, 4
MSB = 03
PLATE1, 2, 3, GM PLATE
MSB = 04, LSB = 0, 7, 16, 17
(Reverb, all the DSP blocks)
LARGE HALL, MEDIUM HALL
MSB = 01, LSB = 2, 3
WARM ROOM, WOODY ROOM
MSB = 02, LSB = 3, 4
RICH PLATE
MSB = 04, LSB = 1
(Reverb block)
DELAY LCR1, DELAY LCR2
MSB = 05
(All the DSP blocks)
DELAY LR
MSB = 06
(All the DSP blocks)
ECHO
MSB = 07
(All the DSP blocks)
CROSS DELAY
MSB = 08
(All the DSP blocks)
No.
Parameter
Display
Value
See Table
Control
1
Reverb Time
0.3 – 30.0s
0 – 69
table#4
2
Diffusion
0 – 10
0 – 10
3
Initial Delay
0.1mS – 200.0mS (*1)
0 – 127
table#5
0.1mS – 99.3mS (*2)
0 – 63
4
HPF Cutoff
Thru – 8.0kHz
0 – 52
table#3
5
LPF Cutoff
1.0kHz – Thru
34 – 60
table#3
6
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
(table#15)
11
Rev Delay
0.1mS – 200.0mS (*1)
0 – 127
table#5
0.1mS – 99.3mS (*2)
0 – 63
12
Density
0 – 4
0 – 4
13
Er/Rev Balance
E63>R – E=R – E<R63
1 – 127
14
High Damp
0.1 – 1.0
1 – 10
15
Feedback Level
-63 – +63
1 – 127
(table#16)
16
No.
Parameter
Display
Value
See Table
Control
1
Reverb Time
0.3 – 30.0s
0 – 69
table#4
2
Diffusion
0 – 10
0 – 10
3
Initial Delay
0.1mS – 200.0mS
0 – 127
table#5
4
HPF Cutoff
Thru – 8.0kHz
0 – 52
table#3
5
LPF Cutoff
1.0kHz – Thru
34 – 60
table#3
6
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
(table#15)
11
12
13
14
High Damp
0.1 – 1.0
1 – 10
15
16
No.
Parameter
Display
Value
See Table
Control
1
Lch Delay
0.1 – 1638.3ms
1 – 16383
2
Rch Delay
0.1 – 1638.3ms
1 – 16383
3
Cch Delay
0.1 – 1638.3ms
1 – 16383
4
Feedback Delay
0.1 – 1638.3ms
1 – 16383
5
Feedback Level
-63 – +63
1 – 127
(table#16)
6
Cch Level
0 – 127
0 – 127
(table#18)
7
High Damp
0.1 – 1.0
1 – 10
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
(table#15)
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table#3
14
EQ Low Gain
-12 – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table#3
16
EQ High Gain
-12 – +12dB
52 – 76
No.
Parameter
Display
Value
See Table
Control
1
Lch Delay
0.1 – 1638.3ms
1 – 16383
2
Rch Delay
0.1 – 1638.3ms
1 – 16383
3
Feedback Delay 1
0.1 – 1638.3ms
1 – 16383
4
Feedback Delay 2
0.1 – 1638.3ms
1 – 16383
5
Feedback Level
-63 – +63
1 – 127
(table#16)
6
High Damp
0.1 – 1.0
1 – 10
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
(table#15)
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table#3
14
EQ Low Gain
-12 – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table#3
16
EQ High Gain
-12 – +12dB
52 – 76
No.
Parameter
Display
Value
See Table
Control
1
Lch Delay1
0.1 – 1486.0ms
1 – 14860
2
Lch Feedback Level
-63 – +63
1 – 127
(table#16)
3
Rch Delay1
0.1 – 1486.0ms
1 – 14860
4
Rch Feedback Level
-63 – +63
1 – 127
(table#16)
5
High Damp
0.1 – 1.0
1 – 10
6
Lch Delay2
0.1 – 1486.0ms
1 – 14860
7
Rch Delay2
0.1 – 1486.0ms
1 – 14860
8
Delay2 Level
0 – 127
0 – 127
(table#18)
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
(table#15)
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table#3
14
EQ Low Gain
-12 – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table#3
16
EQ High Gain
-12 – +12dB
52 – 76
No.
Parameter
Display
Value
See Table
Control
1
L->R Delay
0.1 – 1486.0ms
1 – 14860
2
R->L Delay
0.1 – 1486.0ms
1 – 14860
3
Feedback Level
-63 – +63
1 – 127
(table#16)
4
Input Select
L, R, L&R
0 – 2
5
High Damp
0.1 – 1.0
1 – 10
6
7
8
9
10
Dry/Wet
D63>W – D=W – D<W63
1 – 127
(table#15)
11
12
13
EQ Low Frequency
32Hz – 2.0kHz
4 – 40
table#3
14
EQ Low Gain
-12 – +12dB
52 – 76
15
EQ High Frequency
500Hz – 16.0kHz
28 – 58
table#3
16
EQ High Gain
-12 – +12dB
52 – 76
Parameters marked with a