Yamaha YM-5100A Owner's Manual - Page 13

Adjust the height of the tone bars.

Page 13 highlights

ASSEMBLY YM-4600A/4100A Only 5-2. As YM-4600A/4100A does not have a resonance regulator, insert resonators into resonator holders as shown below. * The resonators are factory adjusted so that the optimum resonance level is obtained at 23°C. If desirable resonance is not available due to the temperature lower or higher than 23°C, adjust setting of the resonators. Move the resonators to fit into longer grooves when the temperature is higher and into shorter grooves when the temperature is lower. Temperature Grooves to use Higher Around 23°C Lower Short groove ("A" in the figure right) Center groove ("B") Long groove ("C") A : For a higher temperature B : For a temperature around 23°C C : For a lower temperature Resonator holder n Adjust the height of the tone bars. While supporting the frame end of the leg by hand, loosen the fixing bolt of the slide guide on both large end and small end sides. Adjust the height to the desired level and tighten the fixing bolts securely. When adjusting the height, use the lines on the slide guide for reference and make the tone bars in parallel with the floor surface. Upon completion of assembly, check to make sure that each bolt is tightened securely. Fixing bolt 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

29
ASSEMBLY
n
Adjust the height of the tone bars.
While supporting the frame end of the leg by hand, loosen the fixing bolt of the slide guide on both large
end and small end sides.
Adjust the height to the desired level and tighten the fixing bolts securely.
When adjusting the height, use the lines on the slide guide for reference and make the tone bars in
parallel with the floor surface.
Upon completion of assembly, check to make sure that each bolt is tightened securely.
5-2.
As YM-4600A/4100A does not have a resonance regulator, insert resonators into resonator holders
as shown below.
YM-4600A/4100A Only
Fixing bolt
* The resonators are factory adjusted so that the optimum resonance level is
obtained at 23
°
C. If desirable resonance is not available due to the
temperature lower or higher than 23
°
C, adjust setting of the resonators.
Move the resonators to fit into longer grooves when the temperature is higher
and into shorter grooves when the temperature is lower.
Resonator
holder
Temperature
Grooves to use
Higher
Short groove
(“A” in the figure right)
Around 23
°
C
Center groove (“B”)
Lower
Long groove (“C”)
A : For a higher temperature
B : For a temperature around 23
°
C
C : For a lower temperature