2016 Polaris SPORTSMAN 450 HO Owners Manual - Page 59

2016 Polaris SPORTSMAN 450 HO Manual

Page 59 highlights

FEATURES AND CONTROLS Instrument Cluster Diagnostic Display Code Definitions Diagnostic Codes Component Throttle Position Sensor 2 Condition Data Valid But Above Normal Operational Range Most Severe Level Data Valid But Below Normal Operational Range Most Severe Level Data Erratic, Intermittent Or Incorrect Voltage Above Normal, Or Shorted To High Source Voltage Below Normal, Or Shorted To Low Source Abnormal Rate Of Change Out Of Calibration Voltage Above Normal, Or Shorted To High Source Voltage Below Normal, Or Shorted To Low Source Current Below Normal Or Open Circuit Data Valid But Above Normal Operating Range Least Severe Level Data Valid But Below Normal Operating Range Least Severe Level Voltage Above Normal, Or Shorted To High Source Voltage Below Normal, Or Shorted To Low Source Current Below Normal Or Open Circuit Data Erratic, Intermittent Or Incorrect Voltage Above Normal, Or Shorted To High Source Voltage Below Normal, Or Shorted To Low Source Current Below Normal Or Open Circuit Condition Exists Data Erratic, Intermittent Or Incorrect Bad Intelligent Device Or Component Data Erratic, Intermittent Or Incorrect Voltage Above Normal, Or Shorted To High Source Voltage Below Normal, Or Shorted To Low Source Abnormal Frequency Or Pulse Width Or Period Condition Exists Condition Exists Condition Exists Condition Exists Condition Exists Condition Exists Data Erratic, Intermittent Or Incorrect Voltage Above Normal, Or Shorted To High Source Voltage Below Normal, Or Shorted To Low Source SPN 520198 520198 520198 520198 520198 520198 520198 520203 520203 520203 520204 520204 520207 520207 520207 520209 520209 520209 520209 520275 520276 520276 520277 520277 520277 520277 520277 520278 520279 520280 520281 520282 520283 520283 520283 FMI 0 1 2 3 4 10 13 3 4 5 15 17 3 4 5 2 3 4 5 31 2 12 2 3 4 8 31 31 31 31 31 31 2 3 4 Active Descent Control System Fuel Correction Front All Wheel Drive Control Circuit Oxygen Sensor Heater 1 Accelerator Position/Brake Position Interaction Throttle Position Sensor (1 or 2 Indeterminable) Throttle Body Control Power Stage Throttle Body Control Return Spring Check Failed Throttle Body Control Adaption Aborted Throttle Body Control Limp Home Position Check Failed Throttle Body Control Mechanical Stop Adaptation Failure Throttle Body Control Repeated Adaptation Failed Throttle Body Control 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179

57
FEATURES AND CONTROLS
Instrument Cluster
Diagnostic Display Code Definitions
Diagnostic Codes
Component
Condition
SPN
FMI
Throttle Position Sensor 2
Data Valid But Above Normal Operational Range -
Most Severe Level
520198
0
Data Valid But Below Normal Operational Range -
Most Severe Level
520198
1
Data Erratic, Intermittent Or Incorrect
520198
2
Voltage Above Normal, Or Shorted To High Source
520198
3
Voltage Below Normal, Or Shorted To Low Source
520198
4
Abnormal Rate Of Change
520198
10
Out Of Calibration
520198
13
Active Descent Control
System
Voltage Above Normal, Or Shorted To High Source
520203
3
Voltage Below Normal, Or Shorted To Low Source
520203
4
Current Below Normal Or Open Circuit
520203
5
Fuel Correction Front
Data Valid But Above Normal Operating Range -
Least Severe Level
520204
15
Data Valid But Below Normal Operating Range -
Least Severe Level
520204
17
All Wheel Drive Control
Circuit
Voltage Above Normal, Or Shorted To High Source
520207
3
Voltage Below Normal, Or Shorted To Low Source
520207
4
Current Below Normal Or Open Circuit
520207
5
Oxygen Sensor Heater 1
Data Erratic, Intermittent Or Incorrect
520209
2
Voltage Above Normal, Or Shorted To High Source
520209
3
Voltage Below Normal, Or Shorted To Low Source
520209
4
Current Below Normal Or Open Circuit
520209
5
Accelerator Position/Brake
Position Interaction
Condition Exists
520275
31
Throttle Position Sensor (1
or 2 Indeterminable)
Data Erratic, Intermittent Or Incorrect
520276
2
Bad Intelligent Device Or Component
520276
12
Throttle Body Control -
Power Stage
Data Erratic, Intermittent Or Incorrect
520277
2
Voltage Above Normal, Or Shorted To High Source
520277
3
Voltage Below Normal, Or Shorted To Low Source
520277
4
Abnormal Frequency Or Pulse Width Or Period
520277
8
Condition Exists
520277
31
Throttle Body Control -
Return Spring Check Failed
Condition Exists
520278
31
Throttle Body Control -
Adaption Aborted
Condition Exists
520279
31
Throttle Body Control -
Limp Home Position Check
Failed
Condition Exists
520280
31
Throttle Body Control -
Mechanical Stop
Adaptation Failure
Condition Exists
520281
31
Throttle Body Control -
Repeated Adaptation
Failed
Condition Exists
520282
31
Throttle Body Control
Data Erratic, Intermittent Or Incorrect
520283
2
Voltage Above Normal, Or Shorted To High Source
520283
3
Voltage Below Normal, Or Shorted To Low Source
520283
4