3Com 3C16700A-US User Guide - Page 25
Dimensions and Standards, Dimensions and Operating Conditions, Standards
UPC - 662705219035
View all 3Com 3C16700A-US manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 25 highlights
DIMENSIONS AND STANDARDS Dimensions and Operating Conditions 0-40°C (32-105°F) operating temperature 0-90% (non-condensing) humidity 225mm (9in.) 35.8mm (1.4in.) 135.4mm (5.3in.) + 15.2mm (0.6in.) for 10BASE-2 port (if applicable) OfficeConnect Ethernet Hub 4 OfficeConnect Ethernet Hub 4C OfficeConnect Ethernet Hub 8 OfficeConnect Ethernet Hub 8C Power 2.33 W 7.96 BThU/hr 10.3 W 35.18 BThU/hr 3.13 W 10.69 BThU/hr 5.53 W 18.89 BThU/hr Weight 500g (1.1 lb) 550g (1.2 lb) 500g (1.1 lb) 550g (1.2 lb) Standards Functional: ISO 8802/3 IEEE 802.3 Safety: EMC: UL 1950 EN 60950 CSA 22.2 #950 IEC 60950 EN 55022 Class B† EN 55024 FCC Part 15 Class B†* ICES-003 Class B VCCI Class B† CNS 13438 Class A Environmental: EN 60068 (IEC 68) Various parts †Category 3 or 5 screened or unscreened cables can be used to ensure compliance with the Class B requirements. *Refer to "Electromagnetic Compatibility" on page 38 for conditions of operation.† 25