3Com 3CB9LF20R Installation Guide - Page 8
Incorrect Value in the Ethernet Display Field (CoreBuilder 3500)
UPC - 662705180977
View all 3Com 3CB9LF20R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
8 70-km Gigabit Ethernet GBIC Transceiver Installation Guide Incorrect Value in the Ethernet Display Field (CoreBuilder 3500) An incorrect value appears in the Ethernet display field when all of these conditions are true: s Your CoreBuilder 3500 is running system software at Release 2.1 or earlier. s You have installed or reinstalled a new or replacement GBIC (for example, Model Number 3CGBIC91, 3CGBIC92 or 3CGBIC97). s You enter the ethernet summary or the ethernet detail command for the first time. When all of these conditions are true, the text (GBIC) Non-qualified appears in the portType field of the Ethernet display even though the GBIC is qualified and functions properly. Disregard this incorrect value. Calculating the Link Budget for the 70-km GBIC Transceiver The 70-km GBIC has an optical budget of 20 dB and operates at a wavelength of 1550 nm. Calculate potential link distances as follows: s Minimum launch power is -4 dBm. s Minimum receive sensitivity is -24 dBm. The optical budget is arrived at by subtracting the minimum receive sensitivity of -24 dBm from the minimum launch power of -4 dBm, which yields an optical budget of 20 dB. s Allow 0.25 dB attenuation per kilometer of single-mode fiber at 1550 nm. s Allow 0.5 dB attenuation per mating connector.