3M™ Super Close Projection System SCP712 Operator's Guide Picture Menu - Advanced The Picture Menu with the Advanced option selected, shown below, is used to adjust the projected image for Computer and Component inputs only. Picture Input Source: Computer 1 Over Scan Color / Brightness Horizontal Position Vertical Position Frequency Phase 97 10 0 0 0 0 Reset Feature Over Scan Description Adjust cropping of image boundaries from 90th to 100th percentile (increments of 1 percent) Brightness / Adjust the white peaking value of the DMD. Color (0 = lowest white peaking value, 10 = highest value) Horizontal Adjust horizontal position of projected image Position (Only for Computer 1 or Computer 2 input source) Vertical Position Adjust vertical position of projected image (Only for Computer 1 or Computer 2 input source) Frequency Adjust the horizontal width of the projected image (Only for Computer 1 or Computer 2 input source) Phase Adjust clock phase to reduce image distortion (Only for Computer 1 or Computer 2 input source) Reset Reset values in Advanced Picture menu only Range 90-100 0-10 N/A N/A -50-+50 -15-+15 N/A Default Video = 97 VGA = 100 Computer = 10 Video = 3 0 0 0 0 N/A © 3M 2008. All Rights Reserved. 16