AEG DK4460-M Product Manual - Page 6

Lighting

Page 6 highlights

6 display Speed 2: the number "2" appears on the display Speed 3: the number "3" appears on the display High-speed: the number "4" appears (flashing) on the display The high-speed function is regulated by a timer. The standard time setting is 5', at the end of which the hood adjusts to speed 2. Press button 2 to deactivate this function before the set time expires; the hood will adjust to speed 1. Press button 1 to turn the hood off. 3. Lights ON/OFF button 4. Speed timer button 5. Display Speed timer button Press button "4" to activate the speed timer; the hood turns off once the set time expires. The timer functions in the following way: • Speed 1 - 20 minutes (the number "1" and a small flashing LED light appear on the display) • Speed 2 - 15 minutes (the number "2" and a small flashing LED light appear on the display) • Speed 3 - 10 minutes (the number "3" and a small flashing LED light appear on the display) • High-speed - 5 minutes (the number "4" and a small flashing LED light appear on the display) Press button 1 or button 4 to turn the hood off while the speed timer is in function; by pressing button 2, the hood returns to the set speed. according to the indications of this manual. When both filter signals appear simultaneously, numbers "1" and "2" will alternately flash on the display. Reset the indicator by performing the abovementioned procedure twice. The first operation resets the grease filter indicator, while the second operation resets the charcoal filter indicator. The charcoal filter indicator is not active in the standard mode. If the hood is used in the recirculation mode, the charcoal filter indicator must be activated. Perform the following steps to activate the charcoal filter indicator: Turn the hood off and keep buttons 2 and 3 pressed for 3". The numbers "1" and "2" will flash for 2" once the function has been activated. Charcoal filter indicator deactivation: Turn the hood off and keep buttons 1 and 2 pressed for 3". The number "1" will flash for 2" to indicate that the function has been deactivated. LIGHTING Disconnect the hood from the electricity. Warning! Prior to touching the light bulbs ensure they are cooled down. Replace with a new 12 Volt, 20 Watt (Maximum) halogen light made for a G-4 base SUITABLE FOR USE IN OPEN LUMINAIRES. Follow package directions and do not touch new light with bare hands. Grease filter indicator After 80 hours of operation, the number "1" starts flashing on the display. Press and hold button 1 for 3" to reset the indicator. Carry out maintenance on the grease filter according to the indications of this manual. Charcoal filter indicator After 320 hours of operation, the number "2" starts flashing on the display. Press and hold button 1 for 3" to reset the indicator. Carry out maintenance on the charcoal filter

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

6
display
Speed 2:
the number “
2
” appears on the
display
Speed 3:
the number “
3
” appears on the
display
High-speed: the number “4” appears
(
ashing) on the display
The high-speed function is regulated by
a timer. The standard time setting is 5’,
at the end of which the hood adjusts to
speed 2.
Press button
2
to deactivate this function
before the set time expires; the hood will
adjust to speed 1. Press button
1
to turn
the hood off.
3. Lights ON/OFF button
4. Speed timer button
5. Display
Speed timer button
Press button “
4
” to activate the speed timer;
the hood turns off once the set time expires.
The timer functions in the following way:
Speed 1
- 20 minutes (the number “
1
and a small
ashing LED light appear on
the display)
Speed 2
- 15 minutes (the number “
2
and a small
ashing LED light appear on
the display)
Speed 3
- 10 minutes (the number “
3
and a small
ashing LED light appear on
the display)
High-speed
- 5 minutes (the number “
4
and a small
ashing LED light appear on
the display)
Press button
1
or button
4
to turn the hood
off while the speed timer is in function; by
pressing button
2
, the hood returns to the
set speed.
Grease
lter indicator
After 80 hours of operation, the number “
1
starts
ashing on the display.
Press and hold button
1
f
or
3"
to reset the
indicator.
Carry out maintenance on the grease
lter
according to the indications of this manual.
Charcoal
lter indicator
After 320 hours of operation, the number “2”
starts
ashing on the display.
Press and hold button
1
f
or
3
"
to reset the
indicator.
Carry out maintenance on the charcoal
lter
according to the indications of this manual.
When
both
lter
signals
appear
simultaneously, numbers “1” and “2” will
alternately
ash on the display.
Reset the indicator by performing the above-
mentioned procedure twice.
The
rst operation resets the grease
lter
indicator, while the second operation resets
the charcoal
lter indicator.
The charcoal
lter indicator is not active in
the standard mode.
If the hood is used in the recirculation
mode, the charcoal
lter indicator must be
activated.
Perform the following steps to activate
the charcoal
lter indicator:
Turn the hood off and keep buttons
2
and
3
pressed for 3”.
The numbers “1” and “2” will
ash for 2” once
the function has been activated.
Charcoal
lter indicator deactivation:
Turn the hood off and keep buttons
1
and
2
pressed for 3”.
The number “1” will
ash for 2” to indicate
that the function has been deactivated.
LIGHTING
Disconnect the hood from the electricity.
Warning!
Prior to touching the light bulbs
ensure they are cooled down.
Replace with a new 12 Volt, 20 Watt
(Maximum) halogen light made for a G-4
base SUITABLE FOR USE IN OPEN
LUMINAIRES.
Follow package directions