AEG HG775450VB User Manual - Page 18

Technical Information

Page 18 highlights

18 www.aeg.com CAUTION! Install the appliance only on a worktop with flat surface. 8.9 Possibilities for insertion The panel installed below the hob must be easy to remove and let an easy access in case a technical assistance intervention is necessary. Kitchen unit with door or drawer A min 40 mm B min 20 mm (max 150 mm) 60 mm A. Removable panel B. Space for connections Kitchen unit with oven The electrical connection of the hob and the oven must be installed separately for safety reasons and to let easy remove oven from the unit. min 6 mm 9. TECHNICAL INFORMATION 9.1 Hob dimensions Width Depth 740 mm 510 mm 9.2 Bypass diameters BURNER Triple Crown Semi-rapid Auxiliary Ø BYPASS 1/100 mm 57 42 32 9.3 Other technical data TOTAL POWER: Electric supply: Gas original: G20 (2H) 20 mbar = 10,5 kW Gas replacement: G30 (3+) 28-30 mbar = 763 g/h G31 (3+) 37 mbar = 750 g/h 220-240 V ~ 50/60 Hz 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

CAUTION!
Install the appliance only on
a worktop with flat surface.
8.9
Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
Kitchen unit with door or drawer
min 6 mm
min 40 mm
60 mm
B
A
min 20 mm
(max 150 mm)
A.
Removable panel
B.
Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9.
TECHNICAL INFORMATION
9.1
Hob dimensions
Width
740 mm
Depth
510 mm
9.2
Bypass diameters
BURNER
Ø BYPASS 1/100 mm
Triple Crown
57
Semi-rapid
42
Auxiliary
32
9.3
Other technical data
TOTAL POWER:
Gas original:
G20 (2H) 20 mbar = 10,5 kW
Gas replacement:
G30 (3+) 28-30 mbar = 763 g/h
G31 (3+) 37 mbar = 750 g/h
Electric supply:
220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
www.aeg.com
18