ASRock B660 Steel Legend User Manual - Page 71

MRC Training Respond Time, ASRock Second Timing Optimization

Page 71 highlights

Configure the memory on die termination resistors' WR for channel B2. ODT NOM (A1) Use this to change ODT (CH A1) Auto/Manual settings. The default is [Auto]. ODT NOM (A2) Use this to change ODT (CH A2) Auto/Manual settings. The default is [Auto]. ODT NOM (B1) Use this to change ODT (CH B1) Auto/Manual settings. The default is [Auto]. ODT NOM (B2) Use this to change ODT (CH B2) Auto/Manual settings. The default is [Auto]. ODT PARK (A1) Configure the memory on die termination resistors' PARK for channel A1. ODT PARK (A2) Configure the memory on die termination resistors' PARK for channel A2. ODT PARK (B1) Configure the memory on die termination resistors' PARK for channel B1. ODT PARK (B2) Configure the memory on die termination resistors' PARK for channel B2. Advanced Setting ASRock Timing Optimization Configure the fast path through the MRC. ASRock Second Timing Optimization Configure the second fast path through the MRC. MRC Training Respond Time Try Slowest MRC Training. Realtime Memory Timing Configure the realtime memory timings. [Enabled] The system will allow performing realtime memory timing changes after 64 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

64
English
Configure the memory on die termination resistors' WR for channel B2.
ODT NOM (A1)
Use this to change ODT (CH A1) Auto/Manual settings. °e default is [Auto].
ODT NOM (A2)
Use this to change ODT (CH A2) Auto/Manual settings. °e default is [Auto].
ODT NOM (B1)
Use this to change ODT (CH B1) Auto/Manual settings. °e default is [Auto].
ODT NOM (B2)
Use this to change ODT (CH B2) Auto/Manual settings. °e default is [Auto].
ODT PARK (A1)
Configure the memory on die termination resistors' PARK for channel A1.
ODT PARK (A2)
Configure the memory on die termination resistors' PARK for channel A2.
ODT PARK (B1)
Configure the memory on die termination resistors' PARK for channel B1.
ODT PARK (B2)
Configure the memory on die termination resistors' PARK for channel B2.
Advanced Setting
ASRock Timing Optimization
Configure the fast path through the MRC.
ASRock Second Timing Optimization
Configure the second fast path through the MRC.
MRC Training Respond Time
Try Slowest MRC Training.
Realtime Memory Timing
Configure the realtime memory timings.
[Enabled] °e system will allow performing realtime memory timing changes aſter