ASRock B660M PG Riptide User Manual - Page 74

E-Core L2 Voltage Mode, Extra Turbo Voltage, E-Core L2 Voltage Offset, Ring Voltage Mode, VF Offset

Page 74 highlights

E-Core L2 Voltage Mode Selects between adaptive and Override Voltage modes. In Override Mode the voltage selected will be applied over all operating frequencies. In Adaptive Mode the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10, 0x11. Extra Turbo Voltage Specifies the extra turbo voltage applied while Atom L2 is operating in turbo mode. Uses Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV. E-Core L2 Voltage Offset Specifies the Offset Voltage applied to the Atom L2 domain. This voltage is specified in millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV. Ring Voltage Mode Selects between adaptive and Override Voltage modes. In Override Mode the voltage selected will be applied over all operating frequencies. In Adaptive Mode the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10, 0x11. Extra Turbo Voltage Specifies the extra turbo voltage applied while ring is operating in turbo mode. Uses Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV. VF Offset Mode Selects between Legacy and Selection modes. Need Reset System after enabling OverClocking Feature to initialize the default value. In Legacy Mode, setting a global offset for the entire VF curve. In Selection modes, setting a selected VF point. Ring Voltage Offset Specifies the Offset Voltage applied to the Ring domain. This voltage is specified in millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV. GT Voltage Mode Selects between adaptive and Override Voltage modes. In Override Mode the voltage selected will be applied over all operating frequencies. In Adaptive Mode the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10, 0x11. Extra Turbo Voltage Specifies the extra turbo voltage applied while GT is operating in turbo mode. Uses Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV. 66 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99

66
English
E-Core L2 Voltage Mode
Selects between adaptive and Override Voltage modes. In Override Mode the
voltage selected will be applied over all operating frequencies. In Adaptive Mode
the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10,
0x11.
Extra Turbo Voltage
Specifies the extra turbo voltage applied while Atom L2 is operating in turbo mode.
Uses Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV.
E-Core L2 Voltage Offset
Specifies the Offset Voltage applied to the Atom L2 domain. °is voltage is specified
in millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV.
Ring Voltage Mode
Selects between adaptive and Override Voltage modes. In Override Mode the
voltage selected will be applied over all operating frequencies. In Adaptive Mode
the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10,
0x11.
Extra Turbo Voltage
Specifies the extra turbo voltage applied while ring is operating in turbo mode. Uses
Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV.
VF Offset Mode
Selects between Legacy and Selection modes. Need Reset System aſter enabling
OverClocking Feature to initialize the default value. In Legacy Mode, setting a
global offset for the entire VF curve. In Selection modes, setting a selected VF point.
Ring Voltage Offset
Specifies the Offset Voltage applied to the Ring domain. °is voltage is specified in
millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV.
GT Voltage Mode
Selects between adaptive and Override Voltage modes. In Override Mode the
voltage selected will be applied over all operating frequencies. In Adaptive Mode
the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10,
0x11.
Extra Turbo Voltage
Specifies the extra turbo voltage applied while GT is operating in turbo mode. Uses
Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV.