ASRock H310M-HDVP User Manual - Page 54
RCOMP2: CMD/CTL Ron Drive Strength
View all ASRock H310M-HDVP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
ODT PARK (A1) Configure the memory on die termination resistors' PARK for channel A. ODT PARK (B1) Configure the memory on die termination resistors' PARK for channel B. COMP Setting RCOMP0: DQ ODT (Read) Default is 121. RCOMP1: DQ /CLK Ron (Drive Strength) Default is 75. RCOMP2: CMD/CTL Ron (Drive Strength) Default is 100. DQ ODT Driving Adjust ODT Driving for better signal. Default is 60. DQ Driving Adjust DQ Driving for better signal. Default is 26. Command Driving Adjust Command Driving for better signal. Default is 20. Control Driving Adjust Control Driving for better signal. Default is 20. Clock Driving Adjust Clock Driving for better signal. Default is 26. DQ Slew Rate Adjust DQ Slew Rate for better signal. Default is 59. Command Slew Rate Adjust Command Slew Rate for better signal. Default is 53 for IN, 89 for 2N. Contorl Slew Rate Adjust Control Slew Rate for better signal. Default is 53. Clock Slew Rate Adjust Clock Slew Rate for better signal. Default is 53. 48 English