ASRock H610TM-ITX User Manual - Page 54

Load User UEFI Setup Profile from Disk

Page 54 highlights

H610TM-ITX global offset for the entire VF curve. In Selection modes, setting a selected VF point. Ring Voltage Offset Specifies the Offset Voltage applied to the Ring domain. This voltage is specified in millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV. GT Voltage Mode Selects between adaptive and Override Voltage modes. In Override Mode the voltage selected will be applied over all operating frequencies. In Adaptive Mode the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10, 0x11. Extra Turbo Voltage Specifies the extra turbo voltage applied while GT is operating in turbo mode. Uses Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV. GT Voltage Offset Specifies the Offset Voltage applied to the GT domain. This voltage is specified in millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV. Save User Default Type a profile name and press enter to save your settings as user default. Load User Default Load previously saved user defaults. Save User UEFI Setup Profile to Disk It helps you to save current UEFI settings as an user profile to disk. Load User UEFI Setup Profile from Disk You can load previous saved profile from the disk. 49 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

H610TM-ITX
49
English
global offset for the entire VF curve. In Selection modes, setting a selected VF point.
Ring Voltage Offset
Specifies the Offset Voltage applied to the Ring domain. °is voltage is specified in
millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV.
GT Voltage Mode
Selects between adaptive and Override Voltage modes. In Override Mode the
voltage selected will be applied over all operating frequencies. In Adaptive Mode
the voltage is interpolated only in turbo mode. Uses Mailbox 0SR 0x150, cmd 0x10,
0x11.
Extra Turbo Voltage
Specifies the extra turbo voltage applied while GT is operating in turbo mode. Uses
Mailbox MSR 0x150, cmd 0x10, 0x11. Range 0-2000 mV.
GT Voltage Offset
Specifies the Offset Voltage applied to the GT domain. °is voltage is specified in
millivolts. Uses Mailbox MSR 0x150, cmd 0x11. Range -500 to 500 mV.
Save User Default
Type a profile name and press enter to save your settings as user default.
Load User Default
Load previously saved user defaults.
Save User UEFI Setup Profile to Disk
It helps you to save current UEFI settings as an user profile to disk.
Load User UEFI Setup Profile from Disk
You can load previous saved profile from the disk.