Acer AL1702 AL1702W Service Guide - Page 8

Electrical Requirements, Standard Test Conditions, Measurement systems - no signal display

Page 8 highlights

Electrical Requirements Standard Test Conditions All tests shall be performed under the following conditions, unless otherwise specified. Ambient light Viewing distance Warm up time All specifications Measuring equipment Control settings User brightness control User contrast control User red/white balance, Green/white balance and Blue/white balance control Power input Ambient temperature Display mode : Dark room : 40 cm for LCD performance, 20 cm for LCD failures : >30 minutes : Chroma 7120 signal generator or equivalent, directly Connected to the monitor under test. Minolta CA100 photometer, or equivalent : Set to Factory preset value (cut off raster) : Set to factory preset value, which allows that the brightest two of 32 linear distributed gray-scales (0~ 700mv) can be distinguished. : In the center (unless otherwise specified) : 230V± 5% : 20+5℃ : 1440x900, 60 Hz, all white Measurement systems The units of measure stated in this document are listed below: 1 gamma = 1 nano tesla 1 tesla = 10,000 gauss cm = in x 2.54 Lb = kg x 2.2 Degrees F = [°C x 1.8] + 32 Degrees C = [°F - 32]/1.8 u' = 4x/(-2x + 12y + 3) v' = 9y/(-2x + 12y + 3) x = (27u'/4)/[(9u'/2) - 12v' + 9] y = (3v')/[(9u'/2) - 12v' + 9] nits = cd/(m2) = Ft-L x 3.426 lux = foot-candle x 10.76 8