Acer Aspire 7552G MSDS, UN38.3, CNAS of Battery pack for transportation - Page 2

Purpose of the Test, Test Quantity, Test Equipment - manual

Page 2 highlights

1. Purpose of the Test: Control Number : SACU0912004 To test each cell/battery is of the type proved to meet the requirements in the Recommendations on the TRANSPORT OF DANGEROUS GOODS, Manual of Tests and Criteria, Fourth revised edition. 2. Test Quantity: 2.1 Four batteries, at first cycle, in fully charged states. (T.1~T.5 test only) 2.2 Four batteries, at first cycles, in fully discharged states. (T.1~T.5 test only) 2.3 Four batteries, after fifty cycles ending in fully charged states. (T.1~T.5 test only) 2.4 Four batteries, after fifty cycles ending in fully discharged states. (T.1~T.5 test only) 2.5 Five component cells, at first cycle at 50% of the design rated capacity. (T.6 test only) 2.6 Five component cells, after fifty cycles ending in fully discharged states. (T.6 test only) 2.7 Four batteries, at first cycle, in fully charged states. (T.7 test only) 2.8 Four batteries, after fifty cycles ending in fully charged states. (T.7 test only) 3. Test Equipment: 3.1 SMP -711 life cycles test system × 32 channel(ML-052,ML-053) 3.2 Vacuum Tank x1(ML-308) 3.3 Agilent -Digit-multi-meter 6 1/2 34401A x1(ML-257) 3.4 Micro-Electronic scale x1(TD-166) 3.5 WIT-Thermal shock chamber x1(ML-018) 3.6 King Design -Vibration Testerx1 (ML-233) 3.7 King Design -Shock tester x1 (ML-056) 3.8 WITGROUP- Programmable Temperature & Humidity Chamberx1 (ML-010) 3.9 YOHAGOWA -DR230 Hybrid Recorder x1 (ML-198) 3.10 YOHAGOWA -MX100 Recorder x1 (ML-068) 3.11 JYI SHENG-Impact tester x1 (ML-076) 3.12 ABM -GCD-5030D-Large power supply x4 (ML-140, ML-141, ML-142, ML-143) The information contained herein is the exclusive property of SIMPLO TECHNOLOGY CO., LTD, and shall not be distributed, reproduced, or disclosed in whole 本or 測in 試pa報rt w告it僅ho對ut上pr述ior測w試rit項ten目p有erm效is,s本io報n This test report is valid only to the items, Invalid for separation using. Page 2 of 5

  • 1
  • 2
  • 3
  • 4
  • 5

Control Number : SACU0912004
The information contained herein is the exclusive property of SIMPLO TECHNOLOGY CO., LTD, and shall not be distributed, reproduced, or disclosed in whole
or in part without prior written permission.
,
This test report is valid only to the items, Invalid for separation using.
Page 2 of 5
1. Purpose of the Test
To test each cell/battery is of the type proved to meet the requirements in the Recommendations
on the TRANSPORT OF DANGEROUS GOODS, Manual of Tests and Criteria, Fourth revised
edition.
2. Test Quantity
2.1
Four batteries, at first cycle, in fully charged states. (T.1~T.5 test only)
2.2
Four batteries, at first cycles, in fully discharged states. (T.1~T.5 test only)
2.3
Four batteries, after fifty cycles ending in fully charged states. (T.1~T.5 test only)
2.4
Four batteries, after fifty cycles ending in fully discharged states. (T.1~T.5 test only)
2.5
Five component cells, at first cycle at 50% of the design rated capacity. (T.6 test only)
2.6
Five component cells, after fifty cycles ending in fully discharged states. (T.6 test only)
2.7
Four batteries, at first cycle, in fully charged states. (T.7 test only)
2.8
Four batteries, after fifty cycles ending in fully charged states. (T.7 test only)
3. Test Equipment
3.1
SMP -711 life cycles test system × 32 channel(ML-052,ML-053)
3.2
Vacuum Tank x1(ML-308)
3.3
Agilent -Digit-multi-meter 6 1/2 34401A x1(ML-257)
3.4
Micro-Electronic scale x1(TD-166)
3.5
WIT-Thermal shock chamber x1(ML-018)
3.6
King Design -Vibration Testerx1 (ML-233)
3.7
King Design -Shock tester x1 (ML-056)
3.8
WITGROUP- Programmable Temperature & Humidity Chamberx1 (ML-010)
3.9
YOHAGOWA –DR230 Hybrid Recorder x1 (ML-198)
3.10
YOHAGOWA –MX100 Recorder x1 (ML-068)
3.11
JYI SHENG-Impact tester x1 (ML-076)
3.12
ABM –GCD-5030D-Large power supply x4 (ML-140, ML-141, ML-142, ML-143)