Acer Aspire Z3170 Acer Aspire Z3170 and Z3171 Desktop Service Guide - Page 14
Power Supply Electrical Design Feature, Security Feature, Thermal Feature, EMI Considerations
View all Acer Aspire Z3170 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Power Supply Electrical Design Feature 0 135W/180W in stable mode (Acer Assign System Power Unit) EPS 2.0 (The maximum no-load power consumption for EPS 2.0 is 0.5W or less for adapters with an output power of 50W to 250W) Input:100~240V~2.4A 50~60HZ Output:19V 7.1A (135W); 19V 9.5A (180W) Security Feature 0 Kensington lock Thermal Feature 0 Adequate venting in the rear of chassis Must Follow Thermal engineering requirement v2.2 RFW in Appendix. EMI Considerations 0 Metal shielding for MB (includes VGA card), touch panel control board. Apply aluminum foil between heatsink and VESA mount. The outside jacket of converter cable, LVDS cable, DVI cable and webcam cable are applying conductive tape, and they fixed on basepan by conductive tape. The ground tab which on RJ45 has to contact with MB shielding. Gasket on MB shielding button side for increase contact area between USB connector and MB shielding. Acoustic Criteria 0 Operating mode: 35 dBA or under (under Windows OS) Idle mode: 28 dBA or under (under Windows OS), please refer to Acer test summary for details Must Follow DT ATX acoustic Engineering RFW V1.2 in Appendix Shock & Vibration Test Criteria 0 Operating frequency 5 ~ 350 Hz Acceleration 0.26 G Sweep Rate 0.5 Octave/Minute Endurance Cycle 1 Cycle (2 sweeps) Test Axis: All possible operating orientation. Test Time: 23 minutes Vibration Unpackaged test (Random) Frequency 5 ~ 500 Hz 1-8 Hardware Specifications and Configurations