Acer P3250 Acer P1350 and P3250 Projector Series Service Guide - Page 63

Function Test & Alignment Procedure, 1 Test Equipment Needed, 2 Service Mode, 3 OSD Reset

Page 63 highlights

Chapter 4 Function Test & Alignment Procedure 4-1 Test Equipment Needed - IBM PC with SVGA/XGA resolution - DVD player with Multi-system (NTSC/PAL/SECAM), equipped "Component", "S-Video" , "Composite" and "HDMI". - HDTV Source (480P, 720P, 1080i) - Minolta CL-100 - Quantum Data 802B or CHROMA2327 (Color Video Signal & Pattern Generator) - After changing parts, check the information below. 4-2 Service Mode 1. Turn on the projector and input the signal 2. Do the following actions sequentially to enter service mode menu (1) Press "Power→Left→Left→Menu". (2) Service mode will be shown. (3) After confirming the configuration, press "Exit" to exit. 4-3 OSD Reset 1. After final QC step, we have to erase all saved change again and restore the OSD default setting. The following actions will allow you to erase all end-users' settings and restore the default setting: (1) Please enter OSD menu. (2) To execute "Reset" function. P3150/P3250/P3150 Refresh/P3250 Refresh Confidential 4-1