Acer TravelMate 6492 Service Guide - Page 125

Undetermined Problems

Page 125 highlights

Undetermined Problems The diagnostic problems does not identify which adapter or device failed, which installed devices are incorrect, whether a short circuit is suspected, or whether the system is inoperative. Follow these procedures to isolate the failing FRU (do not isolate non-defective FRU). Note: Verify that all attached devices are supported by the computer. Note: Verify that the power supply being used at the time of the failure is operating correctly. (See "Power System Check" on page 99.): 1. Power-off the computer. 2. Visually check them for damage. If any problems are found, replace the FRU. 3. Remove or disconnect all of the following devices: q Non-Acer devices q Printer, mouse, and other external devices q Battery pack q Hard disk drive q DIMM q CD-ROM/Diskette drive Module q PC Cards 4. Power-on the computer. 5. Determine if the problem has changed. 6. If the problem does not recur, reconnect the removed devices one at a time until you find the failing FRU. 7. If the problem remains, replace the following FRU one at a time. Do not replace a non-defective FRU: q System board q LCD assembly Chapter 4 115