Chapter 4 Function Test & Alignment Procedure 4-1 Test Equipment Needed - IBM PC with SVGA/XGA resolution - DVD player with Multi-system, equipped "Component", "S-Video","Composite" and "HDMI". - HDTV Source (480P, 720P, 1080i, 1080P) - Minolta CL-100 - Quantum Data 802B or CHROMA2327 (Color Video Signal & Pattern Generator) 4-2 Service Mode 1. Turn on the projector 2. Do the following actions sequentially to get into Service Mode (1) Press "Power", "Left", "Left" and "Menu" buttons sequentially on remote controller. (2) Service Mode will be shown. (3) Choose "Exit" to leave the Service Mode after confirming the configuration. 4-3 OSD Reset 1. After final QC step, we have to erase all saved change again and restore the OSD default setting. The following actions will allow you to erase all end-users' settings and restore the default setting: (1) Please get into OSD menu. (2) To execute "Reset" function. X1161/X1261/X1161A/X1161N/X110/H5360 Confidential 4-