Adaptec 3410S User Guide - Page 25

controller uses the first 16 MB as processor RAM., Adaptec RAID controllers report a cache size 16 MB - 3210s

Page 25 highlights

Storage Manager on ROM The Information tab for a controller displays general information reported by that controller. Fields may have special conditions: Model Serial # NVRAM Ver. Cache Revision FW Type ECC SCSI/ATA Bus Width buses SCSI ID Transfer Host Bus Bus Type Transfer Attached Modules Controller model number Controller serial number Version number for NVRAM settings Amount of installed cache memory Controller firmware revision Firmware type Yes if Error Correction Code (ECC) memory is installed Bus width: 8-bit (Narrow) or 16-bit (Wide) Number of buses on the controller SCSI ID assigned to controller (SCSI only) Maximum possible transfer rate PCI 32-bit or Adaptec 2400A/2100S PCI 64-bit for Adaptec 3200S/3210S/3400S/3410S Host PCI transfer rate: 132 MB/sec for Adaptec 2400A 132 MB/sec for Adaptec 2100S 264 MB/sec for Adaptec 3200S/3400S 528 MB/sec for Adaptec 3210S/3410S Memory modules are reported as Bank x: xxMB ECC, starting with Bank 0. ECC is displayed only when ECC memory is installed. Note: Adaptec RAID controllers report a cache size 16 MB less than the total installed memory value because the controller uses the first 16 MB as processor RAM. 2-14

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

2-14
Storage Manager on ROM
The Information tab for a controller displays general information
reported by that controller. Fields may have special conditions:
Note:
Adaptec RAID controllers report a cache size 16 MB
less than the total installed memory value because the
controller uses the first 16 MB as processor RAM.
Model
Controller model number
Serial #
Controller serial number
NVRAM Ver.
Version number for NVRAM settings
Cache
Amount of installed cache memory
Revision
Controller firmware revision
FW Type
Firmware type
ECC
Yes if Error Correction Code (ECC) memory is
installed
SCSI/ATA Bus
Width
Bus width: 8-bit (Narrow) or 16-bit (Wide)
buses
Number of buses on the controller
SCSI ID
SCSI ID assigned to controller (SCSI only)
Transfer
Maximum possible transfer rate
Host Bus
Bus Type
PCI 32-bit or Adaptec 2400A/2100S
PCI 64-bit
for Adaptec 3200S/3210S/3400S/3410S
Transfer
Host PCI transfer rate:
132 MB/sec for Adaptec 2400A
132 MB/sec for Adaptec 2100S
264 MB/sec for Adaptec 3200S/3400S
528 MB/sec for Adaptec 3210S/3410S
Attached
Modules
Memory modules are reported as
Bank
x
:
xx
MB
ECC
, starting with Bank 0. ECC is displayed only
when ECC memory is installed.