Amana AGR3300XDW Installation Instruction - Page 11
Gas Conversions
UPC - 883049212814
View all Amana AGR3300XDW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
GAS CONVERSIONS WARNING 2. Remove grates. 3. Lift the cooktop by both front corners until the side support rods snap into position. 4. Locate the gas pressure regulator. Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Gas conversions from Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer. LP Gas Conversion WARNING A A. Gas pressure regulator IMPORTANT: Do not remove the gas pressure regulator. 5. With a flat-blade screwdriver, remove the brass cap and flip the brass cap over so that "LP" is visible. NAT A Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. To Convert Gas Pressure Regulator 1. Turn manual shutoff valve to the "closed" position B A C A. To range B. Manual shutoff valve "closed" position C. Gas supply line A. Brass cap 6. Reinstall the cap and tighten with the flat-blade screwdriver. LP A A. Cap 11