Amana AGR3300XDW Installation Instruction - Page 11

Gas Conversions

Page 11 highlights

GAS CONVERSIONS WARNING 2. Remove grates. 3. Lift the cooktop by both front corners until the side support rods snap into position. 4. Locate the gas pressure regulator. Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire. Gas conversions from Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer. LP Gas Conversion WARNING A A. Gas pressure regulator IMPORTANT: Do not remove the gas pressure regulator. 5. With a flat-blade screwdriver, remove the brass cap and flip the brass cap over so that "LP" is visible. NAT A Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. To Convert Gas Pressure Regulator 1. Turn manual shutoff valve to the "closed" position B A C A. To range B. Manual shutoff valve "closed" position C. Gas supply line A. Brass cap 6. Reinstall the cap and tighten with the flat-blade screwdriver. LP A A. Cap 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

11
GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to
Natural gas must be done by a qualified installer.
LP Gas Conversion
To Convert Gas Pressure Regulator
1.
Turn manual shutoff valve to the “closed” position
2.
Remove grates.
3.
Lift the cooktop by both front corners until the side support
rods snap into position.
4.
Locate the gas pressure regulator.
IMPORTANT:
Do not remove the gas pressure regulator.
5.
With a flat-blade screwdriver, remove the brass cap and flip
the brass cap over so that “LP” is visible.
6.
Reinstall the cap and tighten with the flat-blade screwdriver.
A. To range
B. Manual shutoff valve “closed” position
C. Gas supply line
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
A. Gas pressure regulator
A. Brass cap
A. Cap
A
NAT
A
LP
A