To Convert Oven Burner 1. Open the oven door and remove oven racks, oven tray, and flame spreader and set aside. 2. Lift oven burner. The orifice spud is behind the oven burner air shutter. Natural Gas Conversion WARNING A B A. Oven burner B. Air shutter 3. Locate LP gas orifice spud stamped "56" in the bag containing literature supplied with the range. 4. Use a ³⁄₈" combination wrench and remove the Natural gas orifice spud. 5. Install the number "56" LP gas spud. IMPORTANT: Do not overtighten. A A. LP oven orifice spud stamped with "56" 6. Place Natural gas oven burner spud in plastic parts bag along with Natural gas cooktop burner spuds for future use and keep with the bag containing literature. 7. Reinstall oven burner. 8. Reinstall oven racks, oven tray and flame spreader. Complete Conversion 1. Refer to the "Make Gas Connection" section for properly connecting the range to the gas supply. 2. Turn the manual shutoff valve in the gas supply line to the open position. 3. Refer to "Check Operation of Cooktop Burners" in the "Electronic Ignition System" section for proper burner ignition, operation and burner flame adjustments. IMPORTANT: You may have to adjust the "LO" setting for each cooktop burner. Checking for proper cooktop and oven burner flames is very important. The small inner cone should have a very distinct blue flame ¼" to ½" (0.64 cm to 1.3 cm) long. The outer cone is not as distinct as the inner cone. LP gas flames have a slightly yellow tip. 4. Close the oven door and turn the knob to "OFF." 5. Refer to the "Complete Installation" section to complete this procedure. Tip Over Hazard A child or adult can tip the range and be killed. Connect anti-tip bracket to rear range foot. Reconnect the anti-tip bracket, if the range is moved. Failure to follow these instructions can result in death or serious burns to children and adults. To Convert Gas Pressure Regulator 1. Turn manual shutoff valve to the "closed" position. B A C A. To range B. Manual shutoff valve "closed" position C. Gas supply line 2. Unplug range or disconnect power. 3. Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment. A A. Gas pressure regulator IMPORTANT: Do not remove the gas pressure regulator. 4. Remove the cap from the gas pressure regulator using a flat-blade screwdriver. NOTE: Do not remove the spring beneath the cap. A A. Cap 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

13
To Convert Oven Burner
1.
Open the oven door and remove oven racks, oven tray, and
flame spreader and set aside.
2.
Lift oven burner. The orifice spud is behind the oven burner
air shutter.
3.
Locate LP gas orifice spud stamped “56” in the bag
containing literature supplied with the range.
4.
Use a
³⁄₈
" combination wrench and remove the Natural gas
orifice spud.
5.
Install the number “56” LP gas spud.
IMPORTANT:
Do not overtighten.
6.
Place Natural gas oven burner spud in plastic parts bag along
with Natural gas cooktop burner spuds for future use and
keep with the bag containing literature.
7.
Reinstall oven burner.
8.
Reinstall oven racks, oven tray and flame spreader.
Complete Conversion
1.
Refer to the “Make Gas Connection” section for properly
connecting the range to the gas supply.
2.
Turn the manual shutoff valve in the gas supply line to the
open position.
3.
Refer to “Check Operation of Cooktop Burners” in the
“Electronic Ignition System” section for proper burner
ignition, operation and burner flame adjustments.
IMPORTANT:
You may have to adjust the “LO” setting for
each cooktop burner.
Checking for proper cooktop and oven burner flames is very
important. The small inner cone should have a very distinct
blue flame ¼" to ½" (0.64 cm to 1.3 cm) long. The outer cone
is not as distinct as the inner cone. LP gas flames have a
slightly yellow tip.
4.
Close the oven door and turn the knob to “OFF.”
5.
Refer to the “Complete Installation” section to complete this
procedure.
Natural Gas Conversion
To Convert Gas Pressure Regulator
1.
Turn manual shutoff valve to the “closed” position.
2.
Unplug range or disconnect power.
3.
Open broiler door and remove broiler pan. The gas pressure
regulator is located in the back right hand corner of the broiler
compartment.
IMPORTANT:
Do not remove the gas pressure regulator.
4.
Remove the cap from the gas pressure regulator using a
flat-blade screwdriver.
NOTE:
Do not remove the spring beneath the cap.
A. Oven burner
B. Air shutter
A. LP oven orifice spud stamped with “56”
B
A
A
A. To range
B. Manual shutoff valve “closed” position
C. Gas supply line
A. Gas pressure regulator
A. Cap
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip bracket to rear range foot.
Reconnect the anti-tip bracket, if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children and adults.
A
B
C
A