29" and 27" Dryers Gas (U.S.A. and Canada) PRODUCT MODEL NUMBERS NGD4500V, NGD4600Y, NGD4700Y, NGD5100T Installation clearances: The location must be large enough to allow the dryer door to open fully. Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow. 29" Wide Models Dryer Dimensions 27" Wide Models Dryer Dimensions 43 " (1092 mm) 23 ¾" (603 mm) 43 " (1092 mm) 13 ¾" (349 mm) *29 1/2" (749 mm) 27" (687 mm) *29 1/2" (749 mm) 27" (687 mm) A B A. Large opening side-swing door B. Large opening side-swing door Installation Spacing 18"* (457 mm) 14" max.* (356 mm) 48 in.2* (310 cm ) 2 3"* (76 mm) A. Large opening side-swing door B. Large opening side-swing door C. Wide opening side-swing door D. Wide opening hamper door Installation Spacing 18"* (457 mm) 14" max.* (356 mm) 48 in.2* (310 cm )2 24 in.2 * (155 cm )2 1" 29" 1" 1"* 27¾" (25 mm) (737 mm) (25 mm) (25 mm) (705 mm) A B C A. Recessed area B. Side view - closet or confined area C. Closet door with vents 3"* (76 mm) 3"* (76 mm) 1" (25 mm) 24 in2.* 2 (155 cm ) 27" 1" 1"* 29¼" 5½"* (686 mm) (25 mm) (25 mm) (743 mm) (140 mm) A B C A. Recessed area B. Side view - closet or confined area C. Closet door with vents 3"* (76 mm) Installation spacing for recessed area or closet The dimensions shown are for the minimum spacing allowed. ■■ Additional spacing should be considered for ease of installation and servicing. ■■ Additional clearances might be required for wall, door, and floor moldings. ■■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer. ■■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. ■■ Companion appliance spacing should also be considered. *Required spacing W10115228C 02/2012

  • 1
  • 2

29" and 27" Dryers
Gas (U.S.A. and Canada)
PRODUCT MODEL NUMBERS
W10115228C
02/2012
NGD4500V, NGD4600Y,
NGD4700Y, NGD5100T
Installation clearances:
The location must be large enough to allow the dryer door to open fully.
Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow.
A
B
C
18"*
(457 mm)
1"
(25 mm)
29"
(737 mm)
1"
(25 mm)
1"*
(25 mm)
14" max.*
(356
mm)
27
¾"
(705 mm)
48 in.
(310 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
24 in.
(155 cm )
2
*
2
43"
(1092 mm)
*29
1
/
2
"
(749 mm)
27"
(687 mm)
A
23¾"
(603 mm)
43"
(1092 mm)
27"
(687 mm)
*29
1
/
2
"
(749 mm)
13¾"
(349 mm)
B
A
B
C
18"*
(457 mm)
1"
(25 mm)
27"
(686 mm)
1"
(25 mm)
1"*
(25 mm)
14" max.*
(356
mm)
29
¼"
(743 mm)
5
½"*
(140 mm)
48 in.
(310 cm )
2
*
2
24 in.
(155 cm )
2
*
2
3"*
(76 mm)
3"*
(76 mm)
29" Wide Models
Dryer Dimensions
Installation Spacing
27" Wide Models
Dryer Dimensions
A. Large opening side-swing door
B. Large opening side-swing door
C. Wide opening side-swing door
D. Wide opening hamper door
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents
*Required spacing
Installation Spacing
Installation spacing for recessed area or closet
The dimensions shown are for the minimum spacing allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door, and
floor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
A. Large opening side-swing door
B. Large opening side-swing door
A. Recessed area
B. Side view – closet or confined area
C. Closet door with vents