Asko T208CW Design Guide - Page 7
Electrical, Plumbing
View all Asko T208CW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
ASKO DISHWASHERS Electrical The electrical supply should be located in an adjacent cabinet. If the supply cannot be located in an adjacent cabinet, it must be located within the shaded area shown in the illustration below. A separate circuit, servicing only this appliance is required. IMPORTANT NOTE: For the outdoor model, a ground fault circuit interrupter (GFCI) is required to reduce the risk of electrical shock. A GFCI is not recommended for use with other models and may cause interruption of operation. Installation must comply with all applicable electrical codes. ELECTRICAL REQUIREMENTS Electrical Supply Service Receptacle Power Cord 115 VAC, 60 Hz 15 amp dedicated circuit 3-prong grounding-type 4' (1.2 m) Plumbing The water supply and drain should be located in an adjacent cabinet. If they cannot be located in an adjacent cabinet, they must be located within the shaded area shown in the illustration below. The water supply line should be connected to a hot or cold house supply with an easily accessible shut-off valve between the supply and the unit. Installation must comply with all applicable plumbing codes. PLUMBING REQUIREMENTS Water Connection Drain Connection Pressure 6' (1.8 m) PEX tubing with 3/8" NPT female connection 5' (1.5 m) corrugated tubing 4.2-140 psi (.3-9.7 bar) OPENING WIDTH 53/8" (137) AREA EXTENDS 2" (51) FORWARD ON FLOOR Electrical supply location OPENING WIDTH 53/8" (137) AREA EXTENDS 2" (51) FORWARD ON FLOOR Water supply and drain location askona.com/specs | 7