Installation instructions Install in a closet ASKO's front panel controls make it possible to install the washers and dryers in a closet. Make sure there is a ½" (12mm) minimum clearance between units and cabinet or wall. To ensure proper ventilation, we recommend louvered doors, particularly for condenser dryers. Otherwise there must be ventilation openings in the door. See illustration for minimum ventilation openings: Air exhaust Connecting the exhaust duct to the dryer NOTE! You will need to purchase a UL-CSA-approved 4" ridged metal exhaust duct. The dryer is delivered with the stub pipe attached to the rear exhaust outlet, though the exhaust duct can be attached to either the left or the right exhaust outlet. Asko dryers have a "T-style" Asko dryersehxahvaeuast vent that allows you to "aTll-oswtilse"yeoxuhtaocuocsnotnnvenecentcttththtehaedt uct on the rear, duct on the roenatrhoer loenfttohreon the right side left or right side. VeVnetnt TT--tutubbee RReeaarrEExxhhaauusstt Outlet Outlet SidSeidEexhEaxuhsatuOsut tlet Outlet SStutubb ClaCmlapmp DDuucct t (no(nt ostuspupplipeldie)d) The duct must not be assembled with screws or other fasteners that extend into the duct and catch lint. Customer Care Center 23 1-800-898-1879 www.askousa.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Install in a closet
ASKO's front panel controls make it possible to
install the washers and dryers in a closet. Make
sure there is a ½” (12mm) minimum clearance
between units and cabinet or wall. To ensure
proper ventilation, we recommend louvered doors,
particularly for condenser dryers. Otherwise there
must be ventilation openings in the door. See
illustration for minimum ventilation openings:
Air exhaust
Connecting the exhaust duct to the dryer
NOTE!
You will need to purchase a UL-CSA-approved
4" ridged metal exhaust duct. The dryer is
delivered with the stub pipe attached to the rear
exhaust outlet, though the exhaust duct can be
attached to either the left or the right exhaust
outlet.
Vent
T-tube
Rear Exhaust Outlet
de Exhaust Outlet
Stub
Clamp
(not supplied)
Duct
s have a
aust vent that
o connect the
rear or on the
side
.
Stub
Clamp
(not supplied)
Duct
Vent
Side Exhaust
Outlet
Asko dryers have a "T-style"
exhaust vent that allows you to
connect the duct on the rear,
on the left or on the right side
Rear Exhaust
Outlet
T-tube
The duct must not be assembled with screws or
other fasteners that extend into the duct and
catch lint.