Asko T794fi Instruction Manual - Page 25

Connecting the exhaust duct to the Left or, Right Side Outlet, Connecting to a ventilation duct

Page 25 highlights

Installation instructions Connecting the exhaust duct to the Left or Right Side Outlet To connect the exhaust duct to the left or right side outlet, follow the steps below: 1. Using a flathead screw-driver, turn the exhaust outlet cover you plan to use to the right or left to align the tabs holding the cover in place. 2. Remove the exhaust outlet cover. 3. Remove the stub pipe from the rear exhaust outlet and place it in the outlet you plan to use. 4. Push the duct onto the stub pipe and secure it with a clamp. 5. With the duct attached, insert the stub pipe into the hole. It should snap into place. 6. After you push the dryer into place, check for kinks in the duct. 7. Use the exhaust outlet cover you removed from the to cover the rear exhaust outlet. WARNING! To reduce the risk of fire, this appliance must be exhausted OUTDOORS or the equivalent. Never cover the end of the dryer stub or exhaust duct with anything to catch lint, except for UL approved vent basket. Connecting to a ventilation duct You will need a UL-CSA-approved, 4-inch ridged metal exhaust duct. If a flexible duct is used, it must comply with the Outline for Clothes Dryer Transition Duct. Subject 2158A and maximum length of 2.4 m (8 feet). NOTE! The more bends and the longer the duct, the less air will circulate through the machine, which will impede drying performance. We recommend that you cut off any excess exhaust duct and run the duct with as few bends as possible. And make any necessary bends as gentle as possible. NOTE! Maximum duct length of 60 feet. A maximum of 4 elbows may be used, but 4 feet of duct must subtracted from the total vent length for every 90° elbow used. NOTE! When installing in warm climates (77° F and above) with high humidity levels, do not route the air exhaust duct upwards. Examples of installations subtract 4 feet for every 90° elbow Customer Care Center 25 1-800-898-1879 www.askousa.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

Connecting the exhaust duct to the Left or
Right Side Outlet
To connect the exhaust duct to the left or right side
outlet, follow the steps below:
1. Using a flathead screw-driver, turn the exhaust
outlet cover you plan to use to the right or left to
align the tabs holding the cover in place.
2. Remove the exhaust outlet cover.
3. Remove the stub pipe from the rear exhaust outlet
and place it in the outlet you plan to use.
4. Push the duct onto the stub pipe and secure it
with a clamp.
5. With the duct attached, insert the stub pipe into
the hole. It should snap into place.
6. After you push the dryer into place, check for kinks
in the duct.
7. Use the exhaust outlet cover you removed from
the to cover the rear exhaust outlet.
WARNING!
To reduce the risk of fire, this appliance must be
exhausted OUTDOORS or the equivalent. Never
cover the end of the dryer stub or exhaust duct with
anything to catch lint, except for UL approved vent
basket.
Connecting to a ventilation duct
You will need a UL-CSA-approved, 4-inch ridged
metal exhaust duct. If a flexible duct is used, it must
comply with the Outline for Clothes Dryer Transition
Duct. Subject 2158A and maximum length of 2.4 m
(8 feet).
NOTE!
The more bends and the longer the duct, the less
air will circulate through the machine, which will
impede drying performance. We recommend that
you cut off any excess exhaust duct and run the
duct with as few bends as possible. And make any
necessary bends as gentle as possible.
NOTE!
Maximum duct length of 60 feet. A maximum of 4
elbows may be used, but 4 feet of duct must
subtracted from the total vent length for every 90°
elbow used.
NOTE!
When installing in warm climates (77° F and above)
with high humidity levels, do not route the air
exhaust duct upwards.
Examples of
installations
subtract 4 feet
for every 90°
elbow
25
Customer Care Center
1-800-898-1879
www.askousa.com
Installation instructions