Asko W6124XW Use and Care Guide English - Page 58

Program Table

Page 58 highlights

PROGRAM TABLE Prewash Temp. °C Super rinse Agitation level** Spinning speed (rpm) Maximum load (kg) (lbs) Water consumption (approximately, in litres) Power consumption (approximately, kWh) Program duration (approximately, in hours and minutes) Program 1. Everyday wash X HOT X I MAX 12 (26.5) 95 2.80 2:31 2. Standard cotton X WARM X N MAX 12 (26.5) 93 2.00 2:59 3. Mix/Synthetics X WARM X S MAX 4.5 (9.9) 65 0.70 1:57 4. Wool/Hand wash X WARM X H MAX 3 (6.6) 58 0.28 0:52 5. Dark wash X WARM X E MAX 4 (8.8) 50 0.66 1:22 6. Time program X WARM E MAX 2 (4.4) - - - 7. Auto program X WARM X N MAX 12 (26.5) - - - 8. Quick program X COLD X N MIN 4 (8.8) 40 0.50 0:50 9. Heavy X HOT X I MAX 12 (26.5) 103 2.50 2:51 10. Easy care X WARM X E MAX 4.5 (9.9) 65 0.68 2:00 11. Jeans X WARM X S MAX 4.5 (9.9) 52 0.68 1:25 12. Shirts program X WARM X E MAX 4 (8.8) 49 0.65 1:10 13. Sanitize X HOT X I MAX 12 (26.5) 93 2.20 2:29 14. Sports wear X WARM X MAX 4.5 (9.9) 50 0.60 1:02 15. Conditioning X MAX 4.5 (9.9) 15 0.03 0:23 16. Stain program X WARM X MAX 12 (26.5) - - - 17. Bedding program X HOT X N MAX 4.5 (9.9) 52 1.67 2:15 18. Allergy program cotton X HOT X I MAX 12 (26.5) 103 2.50 2:44 19. Allergy program synthetics X HOT X S MAX 4.5 (9.9) 70 1.70 2:42 20. Quick Pro X WARM X N MAX 4 (8.8) 40 0.50 0:59 21. Rinse X N MAX 30 0.06 0:29 22. Spin - MAX - 0.06 0:17 23. Drain - - 0.01 0:01 24. Drum cleaning N MAX - - - ⌑ ECO=Green Mode Cold wash * Half load **Agitation level (I = Intensive rhythm, N = Normal rhythm, E = Extra sensitive rhythm, S = Sensitive rhythm, H = Hand wash rhythm) 1) Test program for connection to cold water supply, pursuant to EN 60456. 2) 40 °C program for testing institutes. The 40 °C option has to be set. The above table includes several examples of the use of energy, water, and time for several different program settings. Actual consumption or duration may vary depending on the water pressure, water hardness, water inlet temperature, room temperature, weight and type of load, changes in power supply, and selected options or settings. In the examples specified here, the draining is set to Normal and no additional options are selected. Maximum or nominal load applies to laundry prepared pursuant to the IEC 60456 standard. 58 Customer Care Center, 1-800-898-1879, www.askona.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

58
Customer Care Center, 1-800-898-1879, www.askona.com
PROGRAM TABLE
Program
Prewash
Temp. °C
Super rinse
Agitation level**
Spinning speed
(rpm)
Maximum load
(kg)
(lbs)
Water consumption
(approximately, in litres)
Power consumption
(approximately, kWh)
Program duration
(approximately, in hours
and minutes)
1. Everyday wash
X
HOT
X
I
MAX
12 (26.5)
95
2.80
2:31
2. Standard cotton
X
WARM
X
N
MAX
12 (26.5)
93
2.00
2:59
3. Mix/Synthetics
X
WARM
X
S
MAX
4.5 (9.9)
65
0.70
1:57
4. Wool/Hand wash
X
WARM
X
H
MAX
3 (6.6)
58
0.28
0:52
5. Dark wash
X
WARM
X
E
MAX
4 (8.8)
50
0.66
1:22
6. Time program
X
WARM
E
MAX
2 (4.4)
-
-
-
7. Auto program
X
WARM
X
N
MAX
12 (26.5)
-
-
-
8. Quick program
X
COLD
X
N
MIN
4 (8.8)
40
0.50
0:50
9. Heavy
X
HOT
X
I
MAX
12 (26.5)
103
2.50
2:51
10. Easy care
X
WARM
X
E
MAX
4.5 (9.9)
65
0.68
2:00
11. Jeans
X
WARM
X
S
MAX
4.5 (9.9)
52
0.68
1:25
12. Shirts program
X
WARM
X
E
MAX
4 (8.8)
49
0.65
1:10
13. Sanitize
X
HOT
X
I
MAX
12 (26.5)
93
2.20
2:29
14. Sports wear
X
WARM
X
MAX
4.5 (9.9)
50
0.60
1:02
15. Conditioning
X
MAX
4.5 (9.9)
15
0.03
0:23
16. Stain program
X
WARM
X
MAX
12 (26.5)
-
-
-
17. Bedding program
X
HOT
X
N
MAX
4.5 (9.9)
52
1.67
2:15
18. Allergy program cotton
X
HOT
X
I
MAX
12 (26.5)
103
2.50
2:44
19. Allergy program
synthetics
X
HOT
X
S
MAX
4.5 (9.9)
70
1.70
2:42
20. Quick Pro
X
WARM
X
N
MAX
4 (8.8)
40
0.50
0:59
21. Rinse
X
N
MAX
30
0.06
0:29
22. Spin
-
MAX
-
0.06
0:17
23. Drain
-
-
0.01
0:01
24. Drum cleaning
N
MAX
-
-
-
ECO=Green Mode
Cold wash
* Half load
**Agitation level (I = Intensive rhythm, N = Normal rhythm, E = Extra sensitive rhythm, S = Sensitive rhythm, H = Hand wash rhythm)
1)
Test program for connection to cold water supply, pursuant to EN 60456.
2)
40 °C program for testing institutes. The 40 °C option has to be set.
The above table includes several examples of the use of energy, water, and time for several di
erent program settings. Actual consumption or duration
may vary depending on the water pressure, water hardness, water inlet temperature, room temperature, weight and type of load, changes in power
supply, and selected options or settings. In the examples speci
ed here, the draining is set to Normal and no additional options are selected.
Maximum or nominal load applies to laundry prepared pursuant to the IEC 60456 standard.