5. Maintenance Pressure Sealer ES-5000 1) General Cleaning Be sure that the room is well ventilated, Switch off the mains power and unplug or disconnect from the mains, Pull out the fold drum and the fold unit, Remove as much paper dust as possible using a soft brush 2) Paper Dust With general use, paper dust will build up inside the machine and can be cleared by suing an can of invertible Air Duster, which will apply a short burst of compressed air and clear any paper dust that may be present. 3) Cleaning Pick up and Fold rollers Clean the pickup roller, aluminum and rubber roller in the Fold unit with roller cleaning fluid such as an alcohol solution. Pickup roller in Gray color Aluminum & Rubber rollers Caution: Please do not use any gasolinic oils since it may damage the surface of the rubber rollers! Avoid breathing the fumes or getting the solution in an open wound or other sensitive areas such as the eyes or mouth! 11