Asus M5A97 PLUS User Guide - Page 43

DRAM Timing Control

Page 43 highlights

2.4.11 DRAM Timing Control The sub-items in this menu allow you to set the DRAM timing control features. Use the and keys to adjust the value. To restore the default setting, type [auto] using the keyboard and press . Changing the values in this menu may cause the system to become unstable! If this happens, revert to the default settings. DRAM CAS# Latency [Auto] You can key in the desired value using the numeric keypad. The values range from 4 to 12. DRAM RAS# to CAS# Delay [Auto] You can key in the desired value using the numeric keypad. The values range from 5 to 12. DRAM RAS# PRE Time [Auto] You can key in the desired value using the numeric keypad. The values range from 5 to 12. DRAM RAS# ACT Time [Auto] You can key in the desired value using the numeric keypad. The values range from 15 to 30. DRAM READ to PRE Time [Auto] You can key in the desired value using the numeric keypad. The values range from 4 to 7. DRAM RAS# to RAS# Delay [Auto] You can key in the desired value using the numeric keypad. The values range from 4 to 7. DRAM WRITE to READ Delay [Auto] You can key in the desired value using the numeric keypad. The values range from 4 to 7. DRAM CAS# write Latency [Auto] You can key in the desired value using the numeric keypad. The values range from 5 to 12. DRAM WRITE Recovery Time [Auto] Configuration options: [Auto] [5] [6] [7] [8] [10] [12] DRAM REF Cycle Time [Auto] Configuration options: [Auto] [90ns] [110ns] [160ns] [300ns] [350ns] DRAM Row Cycle Time [Auto] You can key in the desired value using the numeric keypad. The values range from 11 to 42. DRAM READ to WRITE Delay [Auto] You can key in the desired value using the numeric keypad. The values range from 3 to 17. DRAM WRITE to READ Delay(DD) [Auto] You can key in the desired value using the numeric keypad. The values range from 2 to 10. DRAM WRITE to WRITE Timing [Auto] You can key in the desired value using the numeric keypad. The values range from 2 to 10. ASUS M5A97 PLUS 2-15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

ASUS M5A97 PLUS
2-15
2.4.11
DRAM Timing Control
The sub‑items in this menu allow you to set the DRAM timing control features. Use the
<+> and <‑> keys to adjust the value. To restore the default setting, type [auto] using the
keyboard and press <Enter>.
Changing the values in this menu may cause the system to become unstable! If this
happens, revert to the default settings.
DRAM CAS# Latency [Auto]
You can key in the desired value using the numeric keypad. The values range from 4 to 12.
DRAM RAS# to CAS# Delay [Auto]
You can key in the desired value using the numeric keypad. The values range from 5 to 12.
DRAM RAS# PRE Time [Auto]
You can key in the desired value using the numeric keypad. The values range from 5 to 12.
DRAM RAS# ACT Time [Auto]
You can key in the desired value using the numeric keypad. The values range from 15 to 30.
DRAM READ to PRE Time [Auto]
You can key in the desired value using the numeric keypad. The values range from 4 to 7.
DRAM RAS# to RAS# Delay [Auto]
You can key in the desired value using the numeric keypad. The values range from 4 to 7.
DRAM WRITE to READ Delay [Auto]
You can key in the desired value using the numeric keypad. The values range from 4 to 7.
DRAM CAS# write Latency [Auto]
You can key in the desired value using the numeric keypad. The values range from 5 to 12.
DRAM WRITE Recovery Time [Auto]
Configuration options: [Auto] [5] [6] [7] [8] [10] [12]
DRAM REF Cycle Time [Auto]
Configuration options: [Auto] [90ns] [110ns] [160ns] [300ns] [350ns]
DRAM Row Cycle Time [Auto]
You can key in the desired value using the numeric keypad. The values range from 11 to 42.
DRAM READ to WRITE Delay [Auto]
You can key in the desired value using the numeric keypad. The values range from 3 to 17.
DRAM WRITE to READ Delay(DD) [Auto]
You can key in the desired value using the numeric keypad. The values range from 2 to 10.
DRAM WRITE to WRITE Timing [Auto]
You can key in the desired value using the numeric keypad. The values range from 2 to 10.