Asus P2L-M P2L-M User Manual - Page 21

ASUS P2L-M User's Manual, Mount the Heatsink, Insert the SEC Cartridge

Page 21 highlights

III. INSTALLATION CPU III. INSTALLATION 2. Mount the Heatsink: Place the SEC cartridge face down on a flat surface and lay the heat sink flush on the back (metal side) of the SEC cartridge. Check the orientation of the heatsink against the pictures. The thicker fin must be orientated toward the bottom. The top clamp is wider than the bottom clamp so only this orientation will fit. With a screw driver, push the clamps one at a time into the SEC cartridge. Be sure that the heatsink is firmly pressed against the SEC cartridge. When correctly installed, no light must be showing through between the thermal pad of the heatsink and the SEC cartridge. WARNING! If the heatsink is not mounted tightly against the SEC cartridge, the CPU will overheat. You may install an auxiliary fan to provide adequate circulation across the processor's passive heatsink. (8) (9) Push Clamp Push each end of the clamps until they lock (8) Lock Lock Push Clamp (9) The thermal pad & SEC cartridge should not have a gap! SEC Cartridge with Heatsink (Side View) SEC Cartridge with Heatsink (Top View) 3. Insert the SEC Cartridge: Push the SEC cartridge's two locks inward (the preceding picture shows the locks in the outward position and inward in the picture below). With the heatsink facing the motherboard's chipsets, press the cartridge gently but firmly until it is full inserted. (9) (8) Push lock inward (3) ASUS P2L-M User's Manual 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

ASUS P2L-M User’s Manual
21
III. INSTALLATION
CPU
III.
INSTALLATION
2.
Mount the Heatsink:
Place the SEC cartridge face down on a flat surface and lay
the heat sink flush on the back (metal side) of the SEC cartridge. Check the orien-
tation of the heatsink against the pictures. The thicker fin must be orientated
toward the bottom. The top clamp is wider than the bottom clamp so only this
orientation will fit. With a screw driver, push the clamps one at a time into the
SEC cartridge. Be sure that the heatsink is firmly pressed against the SEC car-
tridge. When correctly installed, no light must be showing through between the
thermal pad of the heatsink and the SEC cartridge.
WARNING!
If the heatsink is not mounted tightly against the SEC cartridge,
the CPU will overheat. You may install an auxiliary fan to provide adequate
circulation across the processor’s passive heatsink.
SEC Cartridge with Heatsink (Side View)
SEC Cartridge with Heatsink (Top View)
Push each end of the clamps until they lock
The thermal pad & SEC cartridge should not have a gap!
Lock
Lock
Push Clamp
Push Clamp
(9)
(8)
(8)
(9)
Push lock inward
(8)
(3)
(9)
3.
Insert the SEC Cartridge:
Push the SEC cartridge’s two locks inward (the
preceding picture shows the locks in the outward position and inward in the
picture below). With the heatsink facing the motherboard’s chipsets, press the
cartridge gently but firmly until it is full inserted.