Asus PRIME X370-PRO PRIME X370-PRO Users ManualEnglish - Page 72
AIO_PUMP/W_PUMP+ Middle Duty Cycle% [60]
View all Asus PRIME X370-PRO manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Chassis Fan 1/2 Middle Temperature [45] Use the or keys to set the value for Chassis Fan Middle Temperature. Chassis Fan 1/2 Middle Duty Cycle(%) [60] Use the or keys to adjust the chassis fan middle duty cycle. The values range from 60% to 100%. Chassis Fan 1/2 Lower Temperature [40] Use the or keys to adjust the chassis fans' lower temperature. The values range from 40°C to 75°C. Chassis Fan 1/2 Min. Duty Cycle(%) [60] Use the or keys to adjust the minimum chassis fan duty cycle. The values range from 60% to 100%. When the chassis temperature is under the lower limit, the chassis fan operates at the minimum duty cycle. AIO_PUMP/W_PUMP+ Control [Disabled] Use the and keys to adjust the AIO_PUMP/W_PUMP+ control. The values range from 20% to 100%. When the AIO_PUMP/W_PUMP+ temperature is under the lower limit, the AIO_PUMP/W_PUMP+ fan will operate at the minimum duty cycle. [Auto] Enables the AIO_PUMP/W_PUMP+ control for 4-pin CPU fan. [Disabled] Disables the AIO_PUMP/W_PUMP+ control feature. [DC Mode] Enable the AIO_PUMP/W_PUMP+ control in DC mode for 3-pin AIO_PUMP/W_PUMP+ fan. [PWM Mode] Enable the AIO_PUMP/W_PUMP+ control in PWM mode for 4-pin AIO_PUMP/W_PUMP+ fan. The following items appear only when you set the AIO_PUMP/W_PUMP+ Control to [Auto], [PWM Mode] or [DC Mode]. AIO_PUMP/W_PUMP+ Upper Temperature [70] Use the or keys to adjust the upper limit of the AIO_PUMP/W_ PUMP+ temperature. The values range from 40°C to 75°C. AIO_PUMP/W_PUMP+ Max. Duty Cycle(%) [100] Use the or keys to adjust the maximum AIO_PUMP/W_PUMP+ duty cycle. The values range from 60% to 100%. When the AIO_PUMP/W_ PUMP+ temperature reaches the upper limit, the AIO_PUMP/W_PUMP+ fan will operate at the maximum duty cycle. AIO_PUMP/W_PUMP+ Middle Temperature [45] Use the or keys to set the value for AIO_PUMP/W_PUMP+ Middle Temperature. AIO_PUMP/W_PUMP+ Middle Duty Cycle(%) [60] Use the or keys to adjust the AIO_PUMP/W_PUMP+ middle duty cycle. The values range from 60% to 100%. AIO_PUMP/W_PUMP+ Lower Temperature [40] Use the or keys to adjust the AIO_PUMP/W_PUMP+' lower temperature. The values range from 40°C to 75°C. AIO_PUMP/W_PUMP+ Min. Duty Cycle(%) [60] Use the or keys to adjust the minimum AIO_PUMP/W_PUMP+ duty cycle. The values range from 60% to 100%. When the AIO_PUMP/W_ PUMP+ temperature is under the lower limit, the AIO_PUMP/W_PUMP+ fan operates at the minimum duty cycle. Chapter 3 3-24 Chapter 3: BIOS Setup