Asus PRIME X570-PRO X570 Series BIOS Manual English - Page 22

VDDCR CPU Voltage

Page 22 highlights

Manual Adjustment This item allows you to set the response time, selecting [Regular] will result in longer reaction times. Configuration options: [Regular] [Medium] [Fast] [Ultra Fast] VDDCR CPU Power Duty Control This item allows you to set the duty cycle of each VRM phase based upon current and/ or temperature. [T.Probe] Sets the buck controller to balance VRM FET temperatures. [Extreme] Sets the buck controller to balance per phase current. DO NOT remove the thermal module. The thermal conditions should be monitored. VDDCR SOC Load line Calibration Configuration options: [Auto] [Level 1] - [Level 5] VDDCR SOC Current Capability Configuration options: [100%] [110%] [120%] [130%] VDDCR SOC Switching Frequency Configuration options: [200] [250] [300] [350] VDDCR SOC Power Phase Control Configuration options: [Optimized] [Extreme] [Manual] The following item appears only when the VDDCR SOC Power Phase Control is set to [Manual]. Manual Adjustment This item allows you to set the response time, selecting [Regular] will result in longer reaction times. Configuration options: [Regular] [Medium] [Fast] [Ultra Fast] VDDCR CPU Voltage Configuration options: [Auto] [Manual Mode] [Offset Mode] The following item appears only when you set the VDDCR CPU Voltage to [Manual Mode]. VDDCR CPU Voltage Override Configuration options: [Auto] [0.750] - [2.000] The following items appear only when you set the VDDCR CPU Voltage to [Offset Mode]. VDDCR CPU Offset Mode Sign [+] To offset the voltage by a positive value. [-] To offset the voltage by a negative value. VDDCR CPU Offset Voltage Configuration options: [Auto] [-0.00625] - [+0.50000] 22 PRIME/PRO/TUF GAMING X570 Series BIOS Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54

22
PRIME/PRO/TUF GAMING X570 Series BIOS Manual
Manual Adjustment
This item allows you to set the response time, selecting
[Regular]
will
result in longer reaction times.
Configuration options: [Regular] [Medium] [Fast] [Ultra Fast]
VDDCR
CPU Power Duty Control
This item allows you to set the duty cycle of each VRM phase based upon current and/
or temperature.
[T.Probe]
Sets the buck controller to balance VRM FET temperatures.
[Extreme]
Sets the buck controller to balance per phase current.
DO NOT remove the thermal module. The thermal conditions should be monitored.
VDDCR SOC Load line Calibration
Configuration options: [Auto] [Level 1] – [Level 5]
VDDCR SOC Current Capability
Configuration options: [100%] [110%] [120%] [130%]
VDDCR SOC Switching Frequency
Configuration options: [200] [250] [300] [350]
VDDCR SOC Power Phase Control
Configuration options: [Optimized] [Extreme] [Manual]
The following item appears only when the
VDDCR
SOC Power Phase Control
is set to
[
Manual
].
Manual Adjustment
This item allows you to set the response time, selecting
[Regular]
will
result in longer reaction times.
Configuration options: [Regular] [Medium] [Fast] [Ultra Fast]
VDDCR CPU Voltage
Configuration options: [Auto] [Manual Mode] [Offset Mode]
The following item appears only when you set the
VDDCR
CPU Voltage
to
[Manual
Mode]
.
VDDCR CPU Voltage Override
Configuration options: [Auto] [0.750] - [2.000]
The following items appear only when you set the
VDDCR
CPU Voltage
to
[Offset Mode]
.
VDDCR CPU Offset Mode Sign
[+]
To offset the voltage by a positive value.
[–]
To offset the voltage by a negative value.
VDDCR CPU Offset Voltage
Configuration options: [Auto] [-0.00625] - [+0.50000]