Asus PRIME X670E-PRO WIFI PRIME PROART TUF GAMING AMD AM5 Series BIOS Manual E - Page 81

Chassis Intrusion Detection Support, AIO Pump Point4 Duty Cycle

Page 81 highlights

AIO Pump Point4 Duty Cycle (%) When the temperature source is lower than the temperature of P4, the duty cycle will be determined according to the P3-P4 and the temperature source. When the temperature source is higher than the temperature of P4, the fan will operate at the duty cycle of P4. Use the or keys to adjust the Point4 temperature. AIO Pump Point3 Temperature When the temperature source is lower than the temperature of P3, the duty cycle will be determined according to the P3-P4 and the temperature source. When the temperature source is higher than the temperature of P3, the duty cycle will be determined according to the P3-P4 and the temperature source. Use the or keys to adjust the Point3 temperature. AIO Pump Point3 Duty Cycle (%) When the temperature source is lower than the temperature of P3, the duty cycle will be determined according to the P3-P4 and the temperature source. When the temperature source is higher than the temperature of P3, the duty cycle will be determined according to the P3-P4 and the temperature source. Use the or keys to adjust the Point3 temperature. AIO Pump Point2 Temperature When the temperature source is lower than the temperature of P2, the duty cycle will be determined according to the P2-P3 and the temperature source. When the temperature source is higher than the temperature of P2, the duty cycle will be determined according to the P2-P3 and the temperature source. Use the or keys to adjust the Point2 temperature. AIO Pump Point2 Duty Cycle (%) When the temperature source is lower than the temperature of P2, the duty cycle will be determined according to the P2-P3 and the temperature source. When the temperature source is higher than the temperature of P2, the duty cycle will be determined according to the P2-P3 and the temperature source. Use the or keys to adjust the Point2 temperature. AIO Pump Point1 Temperature When the temperature source is lower than the temperature of P1, the fan will operate at the duty cycle of P1. When the temperature source is higher than the temperature of P1, the duty cycle will be determined according to the P1-P2 and the temperature source. Use the or keys to adjust the Point1 temperature. AIO Pump Point1 Duty Cycle (%) When the temperature source is lower than the temperature of P1, the fan will operate at the duty cycle of P1. When the temperature source is higher than the temperature of P1, the duty cycle will be determined according to the P1-P2 and the temperature source. Use the or keys to adjust the Point1 temperature. Chassis Intrusion Detection Support Set this item to [Enabled] to enable the chassis intrusion detection function. Configuration options: [Enabled] [Disabled] PRIME / ProArt / TUF GAMING AMD 600 Series BIOS Manual 81

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94

PRIME / ProArt / TUF GAMING AMD 600 Series BIOS Manual
81
AIO Pump Point4 Duty Cycle (%)
When the temperature source is lower than the temperature of P4, the duty cycle
will be determined according to the P3-P4 and the temperature source. When the
temperature source is higher than the temperature of P4, the fan will operate at the
duty cycle of P4. Use the <+> or <-> keys to adjust the Point4 temperature.
AIO Pump Point3 Temperature
When the temperature source is lower than the temperature of P3, the duty cycle
will be determined according to the P3-P4 and the temperature source. When the
temperature source is higher than the temperature of P3, the duty cycle will be
determined according to the P3-P4 and the temperature source. Use the <+> or <->
keys to adjust the Point3 temperature.
AIO Pump Point3 Duty Cycle (%)
When the temperature source is lower than the temperature of P3, the duty cycle
will be determined according to the P3-P4 and the temperature source. When the
temperature source is higher than the temperature of P3, the duty cycle will be
determined according to the P3-P4 and the temperature source. Use the <+> or <->
keys to adjust the Point3 temperature.
AIO Pump Point2 Temperature
When the temperature source is lower than the temperature of P2, the duty cycle
will be determined according to the P2-P3 and the temperature source. When the
temperature source is higher than the temperature of P2, the duty cycle will be
determined according to the P2-P3 and the temperature source. Use the <+> or <->
keys to adjust the Point2 temperature.
AIO Pump Point2 Duty Cycle (%)
When the temperature source is lower than the temperature of P2, the duty cycle
will be determined according to the P2-P3 and the temperature source. When the
temperature source is higher than the temperature of P2, the duty cycle will be
determined according to the P2-P3 and the temperature source. Use the <+> or <->
keys to adjust the Point2 temperature.
AIO Pump Point1 Temperature
When the temperature source is lower than the temperature of P1, the fan will operate
at the duty cycle of P1. When the temperature source is higher than the temperature
of P1, the duty cycle will be determined according to the P1-P2 and the temperature
source. Use the <+> or <-> keys to adjust the Point1 temperature.
AIO Pump Point1 Duty Cycle (%)
When the temperature source is lower than the temperature of P1, the fan will operate
at the duty cycle of P1. When the temperature source is higher than the temperature
of P1, the duty cycle will be determined according to the P1-P2 and the temperature
source. Use the <+> or <-> keys to adjust the Point1 temperature.
Chassis Intrusion Detection Support
Set this item to
[Enabled]
to enable the chassis intrusion detection function.
Configuration options: [Enabled] [Disabled]