Axis Communications P3367-VE P3367-VE - User Manual - Page 57

Ports & Devices, Maintenance, Support

Page 57 highlights

AXIS P3367-VE Fixed Dome Network Camera System Options Ports & Devices I/O Ports The Axis product provides one input port and one output port for connection of external devices. For information about how to connect external devices, see Connectors on page 68. The I/O ports are configured under System Options > Ports & Devices > I/O Ports. The ports can be given descriptive names and their Normal states can be configured as Open circuit or Grounded circuit. Port Status The list on the System Options > Ports & Devices > Port Status page shows the status of the product's input and output ports. Maintenance The Axis product provides several maintenance functions. These are available under System Options > Maintenance. Click Restart to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current settings. Note A restart clears all entries in the Server Report. Click Restore to reset most settings to the factory default values. The following settings are not affected: • the boot protocol (DHCP or static) • the static IP address • the default router • the subnet mask • the system time • the IEEE 802.1X settings • the focus position • uploaded applications are kept but must be restarted Click Default to reset all settings, including the IP address, to the factory default values. This button should be used with caution. The Axis product can also be reset to factory default using the control button, see Reset to Factory Default Settings on page 59. To reset the optics, click Calibrate under System Options > Maintenance > Optics. This may be necessary in situations where the optics has lost its calibration during transport or has been exposed to extreme vibrations. If necessary configure focus and zoom again (see Basic Setup on page 17). To identify the product or test the Status LED, click Flash LED under Identify and specify the duration in seconds, minutes or hours. This can be useful for identifying the product among other products installed in the same location. For information about firmware upgrade, see Upgrade the Firmware on page 60. Support Support Overview The System Options > Support > Support Overview page provides information on troubleshooting and contact information, should you require technical assistance. 57

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

AXISP3367–VEFixedDomeNetworkCamera
SystemOptions
Ports & Devices
I/O Ports
The Axis product provides one input port and one output port for connection of external devices. For information about how to
connect external devices, see
Connectorsonpage68
.
The I/O ports are configured under
System Options > Ports & Devices > I/O Ports
. The ports can be given descriptive names and their
Normal states
can be configured as
Open circuit
or
Grounded circuit
.
Port Status
The list on the
System Options > Ports & Devices > Port Status
page shows the status of the product’s input and output ports.
Maintenance
The Axis product provides several maintenance functions. These are available under
System Options > Maintenance
.
Click
Restart
to perform a correct restart if the Axis product is not behaving as expected. This will not affect any of the current
settings.
Note
A restart clears all entries in the Server Report.
Click
Restore
to reset most settings to the factory default values. The following settings are not affected:
• the boot protocol (DHCP or static)
• the static IP address
• the default router
• the subnet mask
• the system time
• the IEEE 802.1X settings
• the focus position
• uploaded applications are kept but must be restarted
Click
Default
to reset all settings, including the IP address, to the factory default values. This button should be used with caution. The
Axis product can also be reset to factory default using the control button, see
ResettoFactoryDefaultSettingsonpage59
.
To reset the optics, click
Calibrate
under
System Options
>
Maintenance
>
Optics
. This may be necessary in situations where the
optics has lost its calibration during transport or has been exposed to extreme vibrations. If necessary configure focus and zoom
again (see
BasicSetuponpage17
).
To identify the product or test the Status LED, click
Flash LED
under
Identify
and specify the duration in seconds, minutes or hours.
This can be useful for identifying the product among other products installed in the same location.
For information about firmware upgrade, see
UpgradetheFirmwareonpage60
.
Support
Support Overview
The
System Options > Support > Support Overview
page provides information on troubleshooting and contact information,
should you require technical assistance.
57