ENGLISH GB GENERAL Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations. The appliance has been designed for use in the ducting version (air exhaust to the outside - Fig.1B), filtering version (air circulation on the inside - Fig.1A) or with external motor (Fig.1C). SAFETY PRECAUTION EC/2002/96, Waste Electrical and Electronic Equipment (WEEE). By making sure that this appliance is disposed of in a suitable manner, the user is helping to prevent potential damage to the environment or to public health. The symbol on the product or on the accompanying paperwork indicates that the appliance should not be treated as domestic waste, but should be delivered to a suitable electric and electronic appliance recycling collection point. Follow local guidelines when disposing of waste. For more information on the treatment, re-use and recycling of this product, please contact your local authority, domestic waste collection service or the shop where the appliance was purchased. 1. Take care when the cooker hood is operating simultaneously with an open fireplace or burner that depend on the air in the environment and use a fuel source other than electrical energy, as the cooker hood removes the air from the environment which a burner or fireplace need for combustion. The negative pressure in the environment must not exceed 4Pa (4x10-5 bar). Provide adequate ventilation in the environment for a safe operation of the cooker hood. Follow the local laws applicable for external air evacuation. Before connecting the model to the electricity network: - check the data plate (positioned inside the appliance) to ascertain that the voltage and power correspond to the network and the socket is suitable. If in doubt ask a qualified electrician. - If the power supply cable is damaged, it must be replaced with another cable or a special assembly, which may be obtained direct from the manufacturer or from the Technical Assistance Centre. - This device must be hardwired to the mains supply network by connecting to a single phase spur protected by 3A fuse. 2. Warning ! In certain circumstances electrical appliances may be a danger hazard. A) Do not check the status of the filters while the cooker hood is operating B) Do not touch bulbs or adjacent areas, during or straight after prolonged use of the appliance. C) Flambè cooking is prohibited underneath the cooker hood D) Avoid leaving exposed flames and always ensure that the burners are covered as open flames are damaging for the filters and a fire hazard E) Constantly check food frying to avoid overheated oil becoming a fire hazard F) Disconnect the electrical plug prior to any maintenance. G) This appliance is not intended for use by young children or infirm persons without supervision H) Young children should be supervised to ensure they do not play with the appliance I) There shall be adequate ventilation of the room when the rangehood is used at the same time as appliances burning gas or other fuels L) There is a risk of fire if cleaning is not carried out in accordance with the instructions This appliance conforms to the European Directive INSTALLATION INSTRUCTIONS • Assembly and electrical connections must be carried out by specialised personnel. • Wear protective gloves before proceeding with the installation. • Electrical Connection The appliance has been manufactured as a class II, therefore no earth cable is necessary. The connection to the mains is carried out as follows: BROWN = L line BLUE = N neutral If not provided, connect a plug for the electrical load indicated on the description label. Where a plug is provided, the cooker hood must be installed in order that the plug is easily accessible. An omnipolar switch with a minimum opening of 3mm between contacts, in line with the electrical load and local standards, must be placed between the appliance and the network in the case of direct connection to the electrical network. • The minimum distance between the support surfaces of the cooking pots on the cooker top and the lowest part of the cooker hood must be at least 65 cm. If a connection tube composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the cooker hood exhaust to the same conductor used to circulate hot air or for evacuating fumes from other appliances generated by other than an electrical source. Before proceeding with the assembly operations, remove the anti-grease filter(s) (Fig.6) so that the unit is easier to handle. - In the case of assembly of the appliance in the suction version prepare the hole for evacuation of the air. • We recommend the use of an air exhaust pipe with a diameter of 150. If a pipe with a smaller diameter is used, the efficiency of the product may be reduced and its operation may become noisier • If your appliance has been designed for use in habitations supplied with acentralised suction device perform the following operations: -The switch controls opening and closure of a valve using a thermoelectical device. By placing the switch in the ON position, after a minute, the valve opens rotating 90° allowing suction of the stale air. By placing the switch in the OFF - 5 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

- 5 -
ENGLISH
GB
GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations. The appliance
has been designed for use in the ducting version (air exhaust
to the outside – Fig.1B), filtering version (air circulation on the
inside – Fig.1A) or with external motor (Fig.1C).
SAFETY PRECAUTION
1.
Take care when the cooker hood is operating
simultaneously with an open fireplace or burner that depend
on the air in the environment and use a fuel source other
than electrical energy, as the cooker hood removes the air
from the environment which a burner or fireplace need for
combustion. The negative pressure in the environment must
not exceed 4Pa (4x10-5 bar). Provide adequate ventilation
in the environment for a safe operation of the cooker hood.
Follow the local laws applicable for external air evacuation.
Before connecting the model to the electricity network:
- check the data plate (positioned inside the appliance) to
ascertain that the voltage and power correspond to the
network and the socket is suitable. If in doubt ask a qualified
electrician.
- If the power supply cable is damaged, it must be replaced
with another cable or a special assembly, which may be
obtained direct from the manufacturer or from the Technical
Assistance Centre.
- This device must be hardwired to the mains supply network
by connecting to a single phase spur protected by
3A fuse.
2. Warning !
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the filters while the cooker
hood is operating
B) Do not touch bulbs or adjacent areas, during or straight
after prolonged use of the appliance.
C) Flambè cooking is prohibited underneath the cooker
hood
D) Avoid leaving exposed flames and always ensure that
the burners are covered as open flames are
damaging
for the filters and a fire hazard
E) Constantly check food frying to avoid overheated oil
becoming a fire hazard
F) Disconnect the electrical plug prior to any maintenance.
G) This appliance is not intended for use by young
children or infirm persons without supervision
H) Young children should be supervised to ensure they
do not play with the appliance
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels
L) There is a risk of fire if cleaning is not carried out in
accordance with the instructions
This appliance conforms to the European Directive
EC/2002/96, Waste Electrical and Electronic Equipment
(WEEE). By making sure that this appliance is disposed of in
a suitable manner, the user is helping to prevent potential
damage to the environment or to public health.
The
symbol on the product or on the accompanying
paperwork indicates that the appliance should not be
treated as domestic waste, but should be delivered to
a suitable electric and electronic appliance recycling collec-
tion point. Follow local guidelines when disposing of waste.
For more information on the treatment, re-use and recycling
of this product, please contact your local authority, domestic
waste collection service or the shop where the appliance was
purchased.
INSTALLATION INSTRUCTIONS
• Assembly and electrical connections must be carried out
by specialised personnel.
• Wear protective gloves before proceeding with the
installation.
• Electrical Connection
The appliance has been manufactured as a class II, therefore
no earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN =
L
line
BLUE =
N
neutral
If not provided, connect a plug for the electrical load
indicated on the description label. Where a plug is provided,
the cooker hood must be installed in order that the plug is
easily accessible.
An omnipolar switch with a minimum opening of 3mm
between contacts, in line with the electrical load and local
standards, must be placed between the appliance and the
network in the case of direct connection to the electrical
network.
The minimum distance between the support surfaces of
the cooking pots on the cooker top and the lowest part of
the cooker hood must be at least 65 cm.
If a connection
tube composed of two parts is used, the upper part must be
placed outside the lower part. Do not connect the cooker
hood exhaust to the same conductor used to circulate hot air
or for evacuating fumes from other appliances generated by
other than an electrical source. Before proceeding with the
assembly operations, remove the anti-grease filter(s) (Fig.6)
so that the unit is easier to handle.
- In the case of assembly of the appliance in the suction
version prepare the hole for evacuation of the air.
We recommend the use of an air exhaust pipe with a
diameter of 150. If a pipe with a smaller diameter is used, the
efficiency of the product may be reduced and its operation
may become noisier
If your appliance has been designed for use in habitations
supplied with acentralised suction device perform the
following operations:
-The switch controls opening and closure of a valve using
a thermoelectical device. By placing the switch in the
ON
position, after a minute, the valve opens rotating 90° allow-
ing suction of the stale air. By placing the switch in the
OFF