Use And Maintenance

Page 7 highlights

supplied with the product. • This device may be installed in two different ways: 1. Fixing the hood to the lower part of the wall cabinet (Fig.2) - Make 4 holes in the wall cabinet respecting the measurements indicated in figures 2 A-2 C. - Position the hood underneath the wall cabinet and fix it into place using 4 screws (not supplied) suitable for the type of cabinet. 2. Fixing the hood to the wall (Fig.2). - Make 4 holes in the wall cabinet referring to the measurements indicated in figures 2 A-2 B. - Hang the hood on the wall, using the 2 holes H, align it in a horizontal position and fix it definitively to the wall using the two lower safety holes I (Fig. 2B). For the various installations use screws and screw anchors suited to the type of wall (e.g. reinforced concrete, plasterboard, etc.). If the screws and screw anchors are provided with the product, check that they are suitable for the type of wall on which the hood is to be fixed. The hood is already prepared for the version with which it was ordered. The versions may be: - Extraction (Fig. 1A-3) - Filter (Fig. 1B-4-7). - If the hood is an extractor model, the lever C must be positioned as indicated in Fig. 3. - If the hood is a filter model, the lever C must be positioned as indicated in Fig. 4. • Extractor version The appliance expels the fumes through an outside wall or a duct. It is necessary to buy a telescopic pipe in accordance with the standards in use (inflammable) and connect it to flange D (Fig 1A). The flange D is supplied with the product and should be fixed above the air outlet hole of the hood as indicated in Fig. 3. • Filtering version To transform an extractor hood version into a filter hood version, please inquire with your retailer about purchasing charcoal filters. The filters should be fitted to the extraction assembly inside the hood, by centring them and rotating them 90 degrees, until they click into place (Fig. 7). To do this, remove the grille D (Fig. 5). Close the air outlet opening with the plug B, as indicated in Fig. 4. USE AND MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 15 minutes after cooking is terminated in order to completely eliminate cooking vapours and odours. The proper function of the cooker hood is conditioned by the regularity of the maintenance operations, in particular, the active carbon filter. • The anti-grease filters capture the grease particles suspended in the air, and are therefore subject to clogging according to the frequency of the use of the appliance. In order to prevent fire hazard, it is recommendable to clean the filter at a maximum of 2 months by carrying out the following instructions: - Remove the filters from the cooker hood and wash them in a solution of water and neutral liquid detergent, leaving to soak. - Rinse thoroughly with warm water and leave to dry. - The filters may also be washed in the dishwasher. The aluminium panels may alter in colour after several washes. This is not cause for customer complaint nor replacement of panels. • The active carbon filters purify the air that is replaced in the environment. The filters are not washable nor re-useable and must be replaced at maximum every four months. The saturation of the active carbon filter depends on the frequency of use of the appliance, by the type of cooking and the regularity of cleaning the anti-grease filters. • Clean the fan and other surfaces of the cooker hood regularly using a cloth moistened with denatured alcohol or non abrasive liquid detergent. • The illumination installation is designed for use during cooking and not for prolonged general illumination of the environment. Prolonged use of the illumination installation notably reduces the duration of the bulb. • Replacing the acrylic or metal panels To replace the acrylic or metal panels you need to first remove the grille D by pushing the two side buttons B inwards as indicated in figure 5. Remove the two filter clips B (fig. 6) and the acrylic or metal panel C. To reassemble the part, simply perform the procedure in reverse. • Replace incandescent/halogen/fluorescent lamps (Fig.8): Only use lamps of the same type and Wattage installed on the device. • FILTER REMOVAL WARNING - ENSURE THE APPLIANCE IS SWITCHED OFF AT THE MAINS BEFORE REPLACING THE BULBS AND FILTERS. 1. remove the filters by lifting the recessed handle and lift free from the hood frame. 2. To reinstall the filters position in the recess at the rear and press to lock in position. BULB REPALCEMENT 1. Remove the filters 2. Unscrew the bulb in an anti-clock wise direction. 3. After installing the correct replacement bulb, refit the filter. Replacement bulbs can be easily obtained from a good electrical or DIY store. BEFORE CALLING SERVICE/TROUBLE SHOOTING The hood was switched on but the unit does not operate. • Have you plugged in/switched on the power supply at the socket? • Check for a blown fuse/or trip. Extraction is poor • Check and clean the filters if required, if required, if active filters are present replacement filters maybe required. • Check that the exhaust ducting is not obstructed. THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE WARNINGS. - 7 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

supplied with the product.
• This device may be installed in two different ways:
1. Fixing the hood to the lower part of the wall cabinet
(Fig.2)
- Make 4 holes in the wall cabinet respecting the measurements
indicated in figures 2
A
-2
C
.
- Position the hood underneath the wall cabinet and fix it
into place using 4 screws (not supplied) suitable for the type
of cabinet.
2. Fixing the hood to the wall
(Fig.2).
- Make 4 holes in the wall cabinet referring to the measurements
indicated in figures 2
A
-2
B
. - Hang the hood on the wall, using
the 2 holes
H
, align it in a horizontal position and fix it definitively
to the wall using the two lower safety holes
I
(Fig. 2B). For the
various installations use screws and screw anchors suited to
the type of wall (e.g. reinforced concrete, plasterboard, etc.). If
the screws and screw anchors are provided with the product,
check that they are suitable for the type of wall on which the
hood is to be fixed.
The hood is already prepared for the version with which it was
ordered. The versions may be:
-
Extraction
(Fig. 1A-3)
-
Filter
(Fig. 1B-4-7).
- If the hood is an
extractor
model, the lever
C
must be posi-
tioned as indicated in Fig. 3.
- If the hood is a
filter
model, the lever
C
must be positioned
as indicated in Fig. 4.
Extractor version
The appliance expels the fumes through an outside wall or
a duct. It is necessary to buy a telescopic pipe in accordance
with the standards in use (inflammable)
and connect it to
flange
D
(Fig 1A). The flange
D
is supplied with the product
and should be fixed above the air outlet hole of the hood as
indicated in Fig. 3.
• Filtering version
To transform an extractor hood version into a filter hood
version, please inquire with your retailer about purchasing
charcoal filters. The filters should be fitted to the extraction
assembly inside the hood, by centring them and rotating them
90 degrees, until they click into place (Fig. 7). To do this, remove
the grille
D
(Fig. 5). Close the air outlet opening with the plug
B
, as indicated in Fig. 4.
USE AND MAINTENANCE
• It is recommended to operate the appliance prior to cooking.
It is recommended to leave the appliance in operation for 15
minutes after cooking is terminated in order to completely
eliminate cooking vapours and odours.
The proper function of the cooker hood is conditioned by the
regularity of the maintenance operations, in particular, the
active carbon filter.
• The anti-grease filters capture the grease particles suspended
in the air, and are therefore subject to clogging according to
the frequency of the use of the appliance.
In order to prevent fire hazard, it is recommendable to clean
the filter at a maximum of 2 months by carrying out the fol-
lowing instructions:
- Remove the filters from the cooker hood and wash them in a
solution of water and neutral liquid detergent, leaving to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may alter in colour after several washes.
This is not cause for customer complaint nor replacement of
panels.
• The active carbon filters purify the air that is replaced in the
environment.
The filters are not washable nor re-useable and
must be replaced at maximum every four months. The satura-
tion of the active carbon filter depends on the frequency of use
of the appliance, by the type of cooking and the regularity of
cleaning the anti-grease filters.
Clean the fan and other surfaces of the cooker hood regularly
using a cloth moistened with denatured alcohol or non abrasive
liquid detergent.
• The illumination installation is designed for use during cooking
and not for prolonged general illumination of the environment.
Prolonged use of the illumination installation notably reduces
the duration of the bulb.
• Replacing the acrylic or metal panels
To replace the acrylic or metal panels you need to first remove
the grille
D
by pushing the two side buttons
B
inwards as indi-
cated in figure 5. Remove the two filter clips
B
(fig. 6) and the
acrylic or metal panel
C
. To reassemble the part, simply perform
the procedure in reverse.
• Replace incandescent/halogen/fluorescent lamps
(Fig.8):
Only use lamps of the same type and Wattage installed on
the device.
• FILTER REMOVAL
WARNING - ENSURE THE APPLIANCE IS SWITCHED OFF AT
THE MAINS BEFORE REPLACING THE BULBS AND FILTERS.
1. remove the filters by lifting the recessed handle and lift
free from the hood frame.
2. To reinstall the filters position in the recess at the rear
and press to lock in position.
BULB REPALCEMENT
1. Remove the filters
2. Unscrew the bulb in an anti-clock wise direction.
3. After installing the correct replacement bulb, refit the
filter.
Replacement bulbs can be easily obtained from a good
electrical or DIY store.
BEFORE CALLING SERVICE/TROUBLE SHOOTING
The hood was switched on but the unit does not operate.
• Have you plugged in/switched on the power supply at
the socket?
Check for a blown fuse/or trip.
Extraction is poor
Check and clean the filters if required, if required, if ac
-
tive filters are present replacement filters maybe required.
Check that the exhaust ducting is not obstructed.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR
EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE
WARNINGS.