Belkin F5D5131-16 User Guide - Page 15
RFI Emission, Immunity
UPC - 722868510872
View all Belkin F5D5131-16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Information RFI Emission: 1 • Limit class A according to EN 55022:1998, IEC 60601-1-2 (EMC, medical) • Limit class A for harmonic current emission according to 2 EN 61000-3-2/1995 • Limitation of voltage fluctuation and flicker in low-voltage supply 3 system according to EN 61000-3-3/1995 Immunity: 4 • Product family standard according to EN 55024:1998 • Electrostatic Discharge according to EN 61000-4-2:1995 5 (Contact Discharge: ±4kV, Air Discharge: ±8kV) • Radio-frequency electromagnetic field according to EN 61000- 6 4-3:1996 (80-1000MHz with 1kHz AM 80% Modulation: 3V/m) 7 • Electrical fast transient/burst according to EN 61000-4-4:1995 (AC/DC power supply: ±1kV, data/signal lines: ±0.5kV) 8 • Surge immunity test according to EN 61000-4-5:1995 (AC/ DC line to line: ±1kV, AC/DC line to earth: ±2kV) • Immunity to conducted disturbances, induced by radio-frequency fields: EN 61000-4-6:1996 (0.15- 80MHz with 1kHz AM 80% modulation: 3V/m) • Power frequency magnetic field immunity test according to EN 61000-4-8:1993 (1A/m at frequency 50Hz) • Voltage dips, short interruptions, and voltage variations immunity test according to EN 61000-4-11:1994 (>95% reduction @ 10ms, 30% reduction @ 500ms, >95% reduction @ 5000ms) LVD: • EN 60950-1:2001 section 15