Belkin F6C230-RKM-2U Belkin OmniGuard Rackmount UPS Software Manual - Page 13
Please make sure which com port that server, using to connect com port on the UPS.
View all Belkin F6C230-RKM-2U manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
OmniGuardTM UPS Power Management Software This feature provides user to select different language as per the choices given in the ECM Settings Screen. User needs to configure ECM Setting screen, by selecting proper language at installation time. In case user needs to change the language setting, after installation, he needs to relaunch the ECM. Points to be done manually for Multilanguage to work Copying required language fonts For all windows OS, copy fonts in to respected fonts directory for that OS 1. Say for Win NT, copy fonts into Winnt/Fonts directory 2. For Red Hat 8 Linux, copy fonts to /usr/X1186/lib/X11/fonts 3. For Solaris Intel 8, copy fonts to /usr/openwin/lib/X11/fonts OmniGuardTM software is s tructured this way for multi language feature: 1. In Windows OS: Program Files/Web Based Environment Control Manager/Apache Group/Apache/Language 2. In Red Hat 8 Linux OS: /usr/local/apache/Language 3. In Solaris Intel 8 OS: /usr/local/apache/Language The following parameters are configured via the above Settings screen. ?? COM port of UPS NOTE: Please make sure which com port that server using to connect com port on the UPS. ?? SNMP Agent Peer IP Address: Indicate that server IP address. ?? SNMP Read Community ?? SNMP Write Community ?? Broadcast IP Address (for all clients that want to broadcast messages and set the shutdown messages, these changes need to be done here, and it will be amended in the list. 13