Indicators, Light, Status & Description, POWER, Power events, Lamp events, Thermal events
![]() |
View all BenQ MS510 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
Indicators Light Status & Description POWER TEMP LAMP Power events Orange Off Green Flashing Off Green Off Orange Flashing Off Off Stand-by mode Off Powering up Off Normal operation 1. The projector needs 90 seconds to cool down as it was abnormally shut down without the normal cooling down process. Or Off 2. The projector needs to cool for 90 seconds after the power is turned off. Or 3. The projector has shutdown automatically. If you try to re-start the projector, it will shutdown again. Please contact your dealer for assistance. Lamp events The projector has shutdown automatically. If you try to re- Off Off Red start the projector, it will shutdown again. Please contact your dealer for assistance. Off Off Red 1. Flashing 2. The projector needs 90 seconds to cool down. Or Please contact your dealer for assistance. Thermal events Off Red Flashing Off The projector has shutdown automatically. If you try to re- Off Red Off start the projector, it will shutdown again. Please contact your Orange Flashing Off dealer for assistance. Off Maintenance 61