Beretta A400 XPLOR UNICO Beretta A400 Xplor User Manual - Page 34
Storage - recoil pad
View all Beretta A400 XPLOR UNICO manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
REASSEMBLY • Centre the front spacer on the stock bolt tube. Make sure that the indicator showing the desired drop and cast ("C-60-DX" in the diagram) is visible on the spacer. • Reposition the stock. Place the rear plate inside the stock. Make sure that the same marking is visible on the plates. • Use the 13-mm tube spanner to insert the retaining nut of the stock and spring washer and tighten down with tightening torque 1.6 - 1.8 Kgm (Kilogrammeters). The use of a proper dynamometric spanner is recommended. • (Only for Kick Off versions) Insert the Kick Off recoil absorption device into the stock and tighten with the special screws using a Torx T15 screwdriver. • (Only for the Kick Off versions) Mount the Beretta Microcore recoil pad into the Kick Off holes (Only for the Kick Off versions) or onto the stock. Tighten the screws using the Phillips screwdriver. STORAGE WARNING: To reduce the risk of accidents involving children or unauthorised persons, keep your firearm locked away and store the ammunition in a separate locked location! NOTICE: Store the firearm disassembled (barrel/fore-end and receiver/stock) in the supplied case. Before storage, always check the condition of the shotgun and its case. Ensure that they are perfectly dry. Moisture and water drops can damage the shotgun. NOTICE: Do not store the shotgun in a leather or fabric case. These materials attract moisture, even though they may appear to be perfectly dry. EN ! ! ! 35