Biostar P4TDG P4TDG compatibility test report - Page 53

A to 0A, 0A to 10A, 0A to 20A, 0A to 30A, 0A to 40A, 0A to 50A, 0A to 60A, 60A to 0A, 60A to 10A,

Page 53 highlights

Load Step 0A to 0A 0A to 10A 0A to 20A 0A to 30A 0A to 40A 0A to 50A 0A to 60A Transient Min (mV) at pins AC14/AC15 Current Measurement 0 11.80 10 26.80 20 46.80 30 62.80 40 82.00 50 98.00 60 116.00 Load Step 60A to 0A 60A to 10A 60A to 20A 60A to 30A 60A to 40A 60A to 50A 60A to 60A Transient Max (mV) at pins AC14/AC15 Current Measurement 0 114.00 10 94.00 20 78.00 30 58.80 40 38.80 50 18.00 60 6.00 Units mV mV mV mV mV mV mV Units mV mV mV mV mV mV mV 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

53
Transient Min (mV) at pins AC14/AC15
Load Step
Current
Measurement
Units
0A to 0A
0
11.80
mV
0A to 10A
10
26.80
mV
0A to 20A
20
46.80
mV
0A to 30A
30
62.80
mV
0A to 40A
40
82.00
mV
0A to 50A
50
98.00
mV
0A to 60A
60
116.00
mV
Transient Max (mV) at pins AC14/AC15
Load Step
Current
Measurement
Units
60A to 0A
0
114.00
mV
60A to 10A
10
94.00
mV
60A to 20A
20
78.00
mV
60A to 30A
30
58.80
mV
60A to 40A
40
38.80
mV
60A to 50A
50
18.00
mV
60A to 60A
60
6.00
mV