Bosch HMB57152UC Installation Instructions - Page 8

Electrical Installation, Install Appliance, Testing Operation

Page 8 highlights

Electrical Installation The model stated on the front cover is rated at 120V AC, 60 Hz and uses a NEMA 5-15 plug to connect to a dedicated 120 V microwave circuit. Model Connection HMB57152UC NEMA 5-15 HMB50152UC NEMA 5-15 HMB50162UC NEMA 5-15 Circuit Requirements 120 V, 15 Amps 60 Hz 120 V, 60 Hz 120 V, 60 Hz 15 Amps 15 Amps Electrical Requirements: ▯ a three prong grounded outlet ▯ 120 V, 60 Hz, AC only ▯ 15 Amp electrical supply with a fuse or a circuit breaker This product must be connected to a supply circuit of the proper voltage and frequency. Wire size must conform to the requirements of the National Electric Code or the prevailing local code for this rating. The power supply cord and plug should be brought to a separate 20-amp branch circuit single grounded outlet. The outlet box should be located in the area behind the appliance (see section Cabinet Dimensions). The outlet box and supply circuit should be installed by a qualified electrician and conform to the National Electrical Code or the prevailing local code. The voltage used must be the same as specified on this microwave oven. Using a higher voltage is dangerous and may result in a fire or oven damage. Using a lower voltage will cause slow cooking. The manufacturer is not responsible for any damages resulting from the use of the oven with any voltage other than specified. Install Appliance Note: The appliance is heavy. It is advisable to install it with a second person. NOTICE: Before installing the appliance, be sure to verify the cabinet dimensions and electrical connections. Mount to Cabinet 1. Fully insert the appliance and center it. Do not kink the electrical cable. 2. Screw the appliance into place. Testing Operation 1. Turn on power at the breaker. 2. Test the microwave: Place a cup of water into the oven cavity. Follow the instructions in the Use and Care Manual on how to heat a beverage. 3. Verify that the oven light comes on and the water is heated. 8 4. If any of the tests do not result as explained above, contact Service for assistance. Otherwise, the installation is complete at this time.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

8
Electrical Installation
The model stated on the front cover is rated at 120V AC,
60 Hz and uses a NEMA 5-15 plug to connect to a
dedicated 120 V microwave circuit.
Electrical Requirements:
a three prong grounded outlet
120 V, 60 Hz, AC only
15 Amp electrical supply with a fuse or a circuit
breaker
This product must be connected to a supply circuit of the
proper voltage and frequency. Wire size must conform to
the requirements of the National Electric Code or the
prevailing local code for this rating. The power supply
cord and plug should be brought to a separate 20-amp
branch circuit single grounded outlet. The outlet box
should be located in the area behind the appliance (see
section
Cabinet Dimensions
). The outlet box and supply
circuit should be installed by a qualified electrician and
conform to the National Electrical Code or the prevailing
local code.
The voltage used must be the same as specified on this
microwave oven. Using a higher voltage is dangerous
and may result in a fire or oven damage. Using a lower
voltage will cause slow cooking. The manufacturer is not
responsible for any damages resulting from the use of
the oven with any voltage other than specified.
Install Appliance
Note:
The appliance is heavy. It is advisable to install it
with a second person.
NOTICE:
Before installing the appliance, be sure to
verify the cabinet dimensions and electrical connections.
Mount to Cabinet
1.
Fully insert the appliance and center it. Do not kink the
electrical cable.
2.
Screw the appliance into place.
Testing Operation
1.
Turn on power at the breaker.
2.
Test the microwave:
Place a cup of water into the oven cavity. Follow the
instructions in the Use and Care Manual on how to
heat a beverage.
3.
Verify that the oven light comes on and the water is
heated.
4.
If any of the tests do not result as explained above,
contact Service for assistance. Otherwise, the
installation is complete at this time.
Model
Connection
Circuit
Requirements
HMB57152UC
NEMA 5-15
120 V,
60 Hz
15 Amps
HMB50152UC
NEMA 5-15
120 V,
60 Hz
15 Amps
HMB50162UC
NEMA 5-15
120 V,
60 Hz
15 Amps