Bosch NEM5466UC Installation Instructions - Page 6

Electrical Installation

Page 6 highlights

2. Place cooktop into cutout. 3. Insert clamping screws into the bracket and secure cooktop to countertop. Use a wood block to protect fragile countertop materials. Electrical Installation Electrical Requirements You can find the identification plate with the electrical specifications on the underside of the appliance. The junctionbox must be located within 3 feet of the cooktop connection. It should be easily accessible for service purposes.  PP DSSUR[ )LWWLQJ&RQGXLW PP  PP  PP -ER[ &RQGXLWDSSUR[ IHHW aPP Model NEM5466UC 240 V AC, 60 Hz system: circuit breaker 30 Amp 208 V AC, 60 Hz system: circuit breaker 30 Amp Connect Electrical Supply 9 WARNING Before installing, turn off at the service panel. Lock service panel to prevent power from being turned on accidentally. The electrical power supply system should be a 1-phase, 3-wire system with ground connection. Install suitable junction box (not furnished). An appropriately-sized, ULlisted conduit connector must be used to correctly attach the conduit to the junction box. The branch-circuit breakers ampacity, the wire sizes and the connections must be conform to the requirements of the National Electrical Code or Canadian Electrical Code and all local codes and ordinances. Attach flexible conduit to the junction box. 9 WARNING To reduce the risk of electric shock and fire, do not use a flexible power supply cord. Connect the cooktop lead wires to the junction box supply wires in proper phase: black (L1) to black red (L2) to red blank copper wire to ground 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

6
2.
Place cooktop into cutout.
3.
Insert clamping screws into the bracket and secure
cooktop to countertop. Use a wood block to protect
fragile countertop materials.
Electrical Installation
Electrical Requirements
You can find the identification plate with the electrical
specifications on the underside of the appliance. The
junctionbox must be located within 3 feet of the cooktop
connection. It should be easily accessible for service
purposes.
Connect Electrical Supply
9
WARNING
Before installing, turn off at the service panel. Lock
service panel to prevent power from being turned
on accidentally.
The electrical power supply system should be a 1-phase,
3-wire system with ground connection. Install suitable
junction box (not furnished). An appropriately-sized, UL-
listed conduit connector must be used to correctly attach
the conduit to the junction box.
The branch-circuit breakers ampacity, the wire sizes and
the connections must be conform to the requirements of
the National Electrical Code or Canadian Electrical Code
and all local codes and ordinances.
Attach flexible conduit to the junction box.
9
WARNING
To reduce the risk of electric shock and fire, do not
use a flexible power supply cord.
Connect the cooktop lead wires to the junction box
supply wires in proper phase:
black (L1) to black
red (L2) to red
blank copper wire to ground
Model
240 V AC,
60 Hz system:
circuit breaker
208 V AC,
60 Hz system:
circuit breaker
NEM5466UC
30 Amp
30 Amp