Bosch NWC-0495-20P Operating Instructions - Page 23
Alarm connector
View all Bosch NWC-0495-20P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Dinion IP Connections | en 23 2.4 Pin 1 2 3 4 Alarm connector Alarm socket Ground Alarm in Relay out contact 1 Relay out contact 2 Alarm Pin 4 Pin 1 - Max. wire diameter AWG 22-28 for both stranded and solid. - Default relay position n.o. (normally open), no alarm. - Alarm output relay switching capability: Max voltage 30VAC or +40VDC. Max 0.5 A continuous, 10VA. - Alarm in: TTL logic, +5V nominal, +40VDC max, DC coupled with 22kOhm pull-up to +3.3V. - Alarm in: configurable as active low or active high. - Max. 42V allowed between camera ground and each of the relay pins. Fig. 2.4 Network and power connection Bosch Security Systems Operating Instructions V 2.5 | 2007.6
Dinion IP
Connections | en
23
Bosch Security Systems
Operating Instructions
V 2.5 | 2007.6
2.4
Alarm connector
Fig. 2.4
Network and power connection
Alarm
Pin 1
Pin 4
Pin
Alarm socket
1
Ground
2
Alarm in
3
Relay out contact 1
4
Relay out contact 2
- Max. wire diameter AWG 22-28 for both
stranded and solid.
- Default relay position n.o. (normally open),
no alarm.
- Alarm output relay switching capability: Max
voltage 30VAC or +40VDC. Max 0.5 A continu-
ous, 10VA.
- Alarm in: TTL logic, +5V nominal, +40VDC
max, DC coupled with 22kOhm pull-up to
+3.3V.
- Alarm in: configurable as active low or active
high.
- Max. 42V allowed between camera ground
and each of the relay pins.